Evidence map›Paper›PMID 24651880›Full record

ArticleScientific reports2014

Bismuthoxyiodide nanoflakes/titania nanotubes arrayed p-n heterojunction and its application for photoelectrochemical bioanalysis.

Wei-Wei Zhao, Zhao Liu, Shu Shan, Wen-Wen Zhang, Jing Wang, Zheng-Yuan Ma, Jing-Juan Xu, Hong-Yuan Chen

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 52 citations in OpenAlex.

  1. Photoelectrochemical performance of BiOI/TiORoyal Society open science · 2023
    Article
  2. CuSensors (Basel, Switzerland) · 2020
    Article
  3. Preparation of an AgI/CuBiMikrochimica acta · 2019
    Article
  4. One-dimensional TiOAdvanced science (Weinheim, Baden-Wurttemberg, Germany) · 2017
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Wei-Wei ZhaoState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Zhao LiuDepartment of Vascular Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
Shu ShanState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Wen-Wen ZhangDepartment of Vascular Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
Jing WangState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Zheng-Yuan MaState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Jing-Juan XuState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Hong-Yuan ChenState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Nanjing University · CNNanjing Drum Tower Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have developed sensitive detection of cancer biomarker vascular endothelial growth factor (VEGF) using the p-n heterojunction comprised of p-type BiOI nanoflakes (NFs) array and n-type TiO2 nanotubes (NTs) array. Due to the unique arrayed structure and the synergy effect of photoelectrochemistry in the formed p-n junction, the synthesized configuration has superior excitation efficiency and thus excellent photoresponsibility. Then, the fabricated p-n heterojunction was integrated with an exquisite bioassay protocol for addressing VEGF using a sandwich immunoassay with glucosedehydrogenase (GDH) as the enzyme tags. Due to the excellent performance of BiOI NFs array/TiO2 NTs array and the ingenious signaling mechanism, the proposed system could achieve the sensitive and specific VEGF detection. This work not only presents a simple BiOI NFs array/TiO2 NTs array p-n heterojunction for general applications in the broad photochemistry areas, but also opens a different horizon for current development of advanced PEC biomolecular detection.

Indexed as

Electrochemical TechniquesBismuthElectrodesGlucose 1-DehydrogenaseHumansImmunoassayIodidesLightMicroscopy, Electron, ScanningNanostructuresPhotochemical ProcessesSensitivity and SpecificityTitaniumVascular Endothelial Growth Factor ABismuthGlucose 1-DehydrogenaseIodidesTitaniumtitanium dioxideVascular Endothelial Growth Factor A

Identifiers

PMID24651880
PMCPMC3961734
OpenAlexW2006770049

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.