ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2014
Imaging of nitroxides at 250MHz using rapid-scan electron paramagnetic resonance.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- Electron paramagnetic resonance (EPR) meets drug delivery and biomaterials: a magnetic love story.Drug delivery and translational research · 2026Review
- Direct Measurement and Imaging of Redox Status with Electron Paramagnetic Resonance.Antioxidants & redox signaling · 2024Article
- Noninvasive Diagnosis of the Mitochondrial Function of Doxorubicin-Induced Cardiomyopathy Using In Vivo Dynamic Nuclear Polarization-Magnetic Resonance Imaging.Antioxidants (Basel, Switzerland) · 2022Article
- A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress.Applied magnetic resonance · 2021Article
- EPR Everywhere.Applied magnetic resonance · 2021Review
- Rapid-scan EPR imaging of a phantom comprised of species with different linewidths and relaxation times.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Modular imaging system: Rapid scan EPR at 800 MHz.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Tabletop 700 MHz electron paramagnetic resonance imaging spectrometer.Concepts in magnetic resonance. Part B, Magnetic resonance engineering · 2018Article
- Continuous wave electron paramagnetic resonance of nitroxide biradicals in fluid solution.Concepts in magnetic resonance. Part A, Bridging education and research · 2018Article
- Resonators for In Vivo Imaging: Practical Experience.Applied magnetic resonance · 2017Article
- Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Review
- Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo.Journal of visualized experiments : JoVE · 2016Article
- Rapid scan electron paramagnetic resonance at 1.0 GHz of defect centers in γ-irradiated organic solids.Radiation measurements · 2016Article
- Imaging disulfide dinitroxides at 250 MHz to monitor thiol redox status.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015Article
- Electron spin relaxation times and rapid scan EPR imaging of pH-sensitive amino-substituted trityl radicals.Magnetic resonance in chemistry : MRC · 2015Article
- Improved sensitivity for imaging spin trapped hydroxyl radical at 250 MHz.Chemphyschem : a European journal of chemical physics and physical chemistry · 2015Article
- Rapid-Scan EPR of Nitroxide Spin Labels and Semiquinones.Methods in enzymology · 2015Article
- New spectral-spatial imaging algorithm for full EPR spectra of multiline nitroxides and pH sensitive trityl radicals.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2014Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Projections for 2D spectral-spatial images were obtained by continuous wave and rapid-scan electron paramagnetic resonance using a bimodal cross-loop resonator at 251MHz. The phantom consisted of three 4mm tubes containing different (15)N,(2)H-substituted nitroxides. Rapid-scan and continuous wave images were obtained with 5min total acquisition times. For comparison, images also were obtained with 29s acquisition time for rapid scan and 15min for continuous wave. Relative to continuous wave projections obtained for the same data acquisition time, rapid-scan projections had significantly less low-frequency noise and substantially higher signal-to-noise at higher gradients. Because of the improved image quality for the same data acquisition time, linewidths could be determined more accurately from the rapid-scan images than from the continuous wave images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.