Evidence map›Paper›PMID 24648326›Full record

ArticleLasers in surgery and medicine2014

Miniature forward-imaging B-scan optical coherence tomography probe to guide real-time laser ablation.

Zhuoyan Li, Jin H Shen, John A Kozub, Ratna Prasad, Pengcheng Lu, Karen M Joos

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Lasers in surgery and medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Review
  3. Towards OCT-Guided Endoscopic Laser Surgery-A Review.Diagnostics (Basel, Switzerland) · 2023
    Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Motorized Micro-Forceps with Active Motion Guidance based on Common-Path SSOCT for Epiretinal Membranectomy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2017
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Zhuoyan LiVanderbilt School of Medicine, Vanderbilt University, Nashville, Tennessee, 37232.
Jin H Shen
John A Kozub
Ratna Prasad
Pengcheng Lu
Karen M Joos
Vanderbilt University · USVanderbilt Health · US

Funding

Shop Module CoreP30EY008126 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI Kevin L Schey · 1989 to 2026
$19.6M
Intraocular OCT Real-time Monitoring of Laser RetinectomyR21EY019752 · NEI · VANDERBILT UNIVERSITY · PI JOOS, KAREN MARGARET · 2009 to 2010
$426k
NEI NIH HHS 1R21EY019752NEI NIH HHS 5P30EY08126NEI NIH HHS P30 EY008126NEI NIH HHS R21 EY019752
6 · The paper itself

Abstract

BACKGROUND AND

objectiveInvestigations have shown that pulsed lasers tuned to 6.1 µm in wavelength are capable of ablating ocular and neural tissue with minimal collateral damage. This study investigated whether a miniature B-scan forward-imaging optical coherence tomography (OCT) probe can be combined with the laser to provide real-time visual feedback during laser incisions. STUDY DESIGN/METHODS AND MATERIALS: A miniature 25-gauge B-scan forward-imaging OCT probe was developed and combined with a 250 µm hollow-glass waveguide to permit delivery of 6.1 µm laser energy. A gelatin mixture and both porcine corneal and retinal tissues were simultaneously imaged and lased (6.1 µm, 10 Hz, 0.4-0.7 mJ) through air. The ablation studies were observed and recorded in real time. The crater dimensions were measured using OCT imaging software (Bioptigen, Durham, NC). Histological analysis was performed on the ocular tissues.

resultsThe combined miniature forward-imaging OCT and mid-infrared laser-delivery probe successfully imaged real-time tissue ablation in gelatin, corneal tissue, and retinal tissue. Application of a constant number of 60 pulses at 0.5 mJ/pulse to the gelatin resulted in a mean crater depth of 123 ± 15 µm. For the corneal tissue, there was a significant correlation between the number of pulses used and depth of the lased hole (Pearson correlation coefficient = 0.82; P = 0.0002). Histological analysis of the cornea and retina tissues showed discrete holes with minimal thermal damage.

conclusionsA combined miniature OCT and laser-delivery probe can monitor real-time tissue laser ablation. With additional testing and improvements, this novel instrument has the future possibility of effectively guiding surgeries by simultaneously imaging and ablating tissue.

Indexed as

AnimalsCorneaLasers, Solid-StateOphthalmologic Surgical ProceduresRetinaSwineTomography, Optical Coherenceablationcorneaeyegelatinmid-infraredophthalmologyretinawaveguide

Identifiers

PMID24648326
PMCPMC3962956
OpenAlexW1931295675

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.