Evidence map›Paper›PMID 24643383›Full record

ArticleKorean journal of radiology

Monopolar radiofrequency ablation using a dual-switching system and a separable clustered electrode: evaluation of the in vivo efficiency.

Jeong Hee Yoon, Jeong Min Lee, Eui Jin Hwang, In Pyung Hwang, Jeehyun Baek, Joon Koo Han, Byung Ihn Choi

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jeong Hee YoonDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea.
Jeong Min LeeDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea.
Eui Jin HwangDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea.
In Pyung HwangDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea.
Jeehyun BaekDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea.
Joon Koo HanDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea.
Byung Ihn ChoiDepartment of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea.
Seoul National University Hospital · KRSeoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND

methodsThirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups.

resultsNo pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm(3) vs. 20.8 ± 10.7 cm(3); p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29).

conclusionDual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time.

Indexed as

ElectrodesAnimalsCatheter AblationFeasibility StudiesLiverMaleSus scrofaTime FactorsExperimental studyInterventional proceduresLiverRadiofrequency ablationThermal ablation

Identifiers

PMID24643383
PMCPMC3955790
OpenAlexW2119995910

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.