Evidence map›Paper›PMID 24637712›Full record

ArticleJournal of visualized experiments : JoVE2014

The Xenopus oocyte cut-open vaseline gap voltage-clamp technique with fluorometry.

Michael W Rudokas, Zoltan Varga, Angela R Schubert, Alexandra B Asaro, Jonathan R Silva

Open access · bronzeAbstract readVideo-Audio Media
In one paragraph

Article in Journal of visualized experiments : JoVE, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 25 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Mechanisms of noncovalent β subunit regulation of NaThe Journal of general physiology · 2017
    Article
  12. Article
  13. Regulation of NaThe Journal of general physiology · 2017
    Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Michael W RudokasDepartment of Biomedical Engineering, Washington University in St. Louis.
Zoltan VargaDepartment of Biomedical Engineering, Washington University in St. Louis.
Angela R SchubertDepartment of Biomedical Engineering, Washington University in St. Louis.
Alexandra B AsaroDepartment of Biomedical Engineering, Washington University in St. Louis.
Jonathan R SilvaDepartment of Biomedical Engineering, Washington University in St. Louis; jonsilva@wustl.edu.
Washington University in St. Louis · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The cut-open oocyte Vaseline gap (COVG) voltage clamp technique allows for analysis of electrophysiological and kinetic properties of heterologous ion channels in oocytes. Recordings from the cut-open setup are particularly useful for resolving low magnitude gating currents, rapid ionic current activation, and deactivation. The main benefits over the two-electrode voltage clamp (TEVC) technique include increased clamp speed, improved signal-to-noise ratio, and the ability to modulate the intracellular and extracellular milieu. Here, we employ the human cardiac sodium channel (hNaV1.5), expressed in Xenopus oocytes, to demonstrate the cut-open setup and protocol as well as modifications that are required to add voltage clamp fluorometry capability. The properties of fast activating ion channels, such as hNaV1.5, cannot be fully resolved near room temperature using TEVC, in which the entirety of the oocyte membrane is clamped, making voltage control difficult. However, in the cut-open technique, isolation of only a small portion of the cell membrane allows for the rapid clamping required to accurately record fast kinetics while preventing channel run-down associated with patch clamp techniques. In conjunction with the COVG technique, ion channel kinetics and electrophysiological properties can be further assayed by using voltage clamp fluorometry, where protein motion is tracked via cysteine conjugation of extracellularly applied fluorophores, insertion of genetically encoded fluorescent proteins, or the incorporation of unnatural amino acids into the region of interest(1). This additional data yields kinetic information about voltage-dependent conformational rearrangements of the protein via changes in the microenvironment surrounding the fluorescent molecule.

Indexed as

AnimalsFemaleFluorometryHumansNAV1.5 Voltage-Gated Sodium ChannelOocytesPatch-Clamp TechniquesXenopus laevisNAV1.5 Voltage-Gated Sodium Channel

Identifiers

PMID24637712
PMCPMC4145744
OpenAlexW1984731037

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.