In silico study of low-frequency transcranial ultrasound fields in acute ischemic stroke patients.
Article in Ultrasound in medicine & biology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Transcranial ultrasound tomography for brain imaging: Ex vivo results and potential for stroke imaging.Medical physics · 2025Article
- Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025Review
- Effect of Recombinant Tissue Plasminogen Activator and 120-kHz Ultrasound on Porcine Intracranial Thrombus Density.Ultrasound in medicine & biology · 2023Article
- Comparison between MR and CT imaging used to correct for skull-induced phase aberrations during transcranial focused ultrasound.Scientific reports · 2022Article
- Recent ultrasound advancements for the manipulation of nanobiomaterials and nanoformulations for drug delivery.Ultrasonics sonochemistry · 2021Review
- The promising shadow of microbubble over medical sciences: from fighting wide scope of prevalence disease to cancer eradication.Journal of biomedical science · 2021Review
- Transcranial focused ultrasound phase correction using the hybrid angular spectrum method.Scientific reports · 2021Article
- Accelerated sonothrombolysis with Definity in a xenographic porcine cerebral thromboembolism model.Scientific reports · 2021Article
- Advances in Sonothrombolysis Techniques Using Piezoelectric Transducers.Sensors (Basel, Switzerland) · 2020Review
- The effect of 220 kHz insonation scheme on rt-PA thrombolytic efficacy in vitro.Physics in medicine and biology · 2019Article
- In vitro characterization of sonothrombolysis and echocontrast agents to treat ischemic stroke.Scientific reports · 2019Article
- A rapid beam simulation framework for transcranial focused ultrasound.Scientific reports · 2019Article
- Article
- Microfluidic manufacture of rt-PA -loaded echogenic liposomes.Biomedical microdevices · 2016Article
- Sonothrombolysis.Advances in experimental medicine and biology · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Ultrasound in the sub-megahertz range enhances thrombolysis and may be applied transcranially to ischemic stroke patients. The consistency of transcranial insonification needs to be evaluated. Acoustic and thermal simulations based on computed-tomography (CT) scans of 20 patients were performed. An unfocused 120-kHz transducer allowed homogeneous insonification of the thrombus, and positioning based on external landmarks performed similarly to an optimized placement based on CT data. With a weakly focused 500-kHz transducer, the landmark-based positioning underperformed. The predicted inter-patient variation of in situ acoustic pressure was similar with both the 120 and 500-kHz transducers for the optimized placement (18.0-26.4% relative standard deviation). The simulated maximum acoustic pressure in intervening tissues was 2.6 ± 0.6 and 2.0 ± 0.7 times the pressure in the thrombus for the 120-kHz and 500-kHz transducers, respectively. A 1 W/cm(2) insonification of the thrombus caused a 3.8 ± 2.2 °C increase in the bone for the 120-kHz transducer, and a 13.4 ± 3.3 °C increase for the 500-kHz transducer. Contralateral local maxima up to 1.1 times the pressure amplitude in the targeted zone were predicted for the 120-kHz transducer. We established two transducer placement approaches, one based on analysis of a head CT and the other using simple external, visible landmarks. Both approaches allowed consistent insonification of the thrombus.