Evidence map›Paper›PMID 24628752›Full record

ArticleAcademic emergency medicine : official journal of the Society for Academic Emergency Medicine2014

Reducing blood culture contamination in community hospital emergency departments: a multicenter evaluation of a quality improvement intervention.

Wesley H Self, Joyce Mickanin, Carlos G Grijalva, Freda H Grant, Michelle C Henderson, Glenda Corley, D Glen Blaschke Ii, Candace D McNaughton, Tyler W Barrett, Thomas R Talbot and 1 more

Abstract readMulticenter Study
In one paragraph

Article in Academic emergency medicine : official journal of the Society for Academic Emergency Medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Patient-specific risk factors contributing to blood culture contamination.Antimicrobial stewardship & healthcare epidemiology : ASHE · 2022
    Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Impact of bacteremia prediction rule in CAP: Before and after study.The American journal of emergency medicine · 2018
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wesley H SelfThe Department of Emergency Medicine, Vanderbilt University School of Medicine, Nashville, TN.
Joyce Mickanin
Carlos G Grijalva
Freda H Grant
Michelle C Henderson
Glenda Corley
D Glen Blaschke Ii
Candace D McNaughton
Tyler W Barrett
Thomas R Talbot
Barbara R Paul

Funding

The Vanderbilt Emergency Medicine Research Training Program (VEMRT)K12HL109019 · NHLBI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI COLLINS, SEAN PATRICK, STORROW, ALAN B · 2011 to 2015
$3.7M
The Vanderbilt Institute for Clinical and Translational Research (VICTR)KL2TR000446 · NCATS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BERNARD, GORDON RAPHAEL · 2012 to 2016
$2.8M
NCATS NIH HHS KL2 TR000446NHLBI NIH HHS K12 HL109019
6 · The paper itself

Abstract

objectivesBlood culture contamination is a common and preventable problem in the emergency department (ED). In a previous single-center study, changing the process of ED blood culture collection from the traditional "clean," nonsterile procedure to a fully sterile procedure with standardized use of sterile gloves, large-volume chlorhexidine skin antisepsis, and fenestrated sterile drapes resulted in a substantial reduction in contamination. The objective of the current study was to evaluate the effectiveness of this sterile blood culture collection process for reducing blood culture contamination in two community hospital EDs.

methodsThe authors implemented the sterile blood culture collection process in the ED of two hospitals, including Hospital A, which historically had a contamination rate of approximately 5%, and Hospital B, with a 2.5% historical contamination rate. With an interrupted times-series design and segmented regression analysis to adjust for secular trends and autocorrelation, the monthly percentages of cultures contaminated at each hospital during an intervention period (sterile technique) were compared to a 10-month baseline period immediately preceding implementation (clean technique). At Hospital A, the full sterile blood culture collection process was used throughout the 16-month intervention period. At Hospital B, user feedback indicated poor adherence to the process due to difficulty implementing the fenestrated drape component; therefore, the process was simplified to the modified sterile collection process, in which the fenestrated drape component was dropped and sterile gloves and large-volume skin antisepsis were emphasized. Hence, at Hospital B, two intervention periods were compared to the baseline period: the 8-month intervention period 1 (full sterile process) and the subsequent 8-month intervention period 2 (modified sterile process).

resultsAt Hospital A, during the baseline period, 165 of 3,417 (4.83%) cultures were contaminated, while 142 of 5,238 (2.71%) were contaminated during the intervention period (p < 0.01). In the segmented regression model, the full sterile blood culture collection process was associated with an immediate 2.68% (95% confidence interval [CI] = 1.43% to 3.52%) absolute reduction in contamination and sustained reductions during the entire intervention period. At Hospital B, during the baseline, 63 of 2,509 (2.51%) cultures were contaminated. In intervention period 1 with the full sterile process, 51 of 1,865 (2.73%) cultures were contaminated (p = 0.65), with segmented regression results showing no changes compared to baseline. After simplification of the process to address poor adherence, the modified sterile process during intervention period 2 was associated with a significant reduction in contamination, with 17 of 1,860 (0.91%) cultures contaminated (p < 0.01 compared to baseline). The segmented regression model demonstrated the modified sterile process was associated with an immediate 1.53% (95% CI = 1.00% to 1.88%) absolute reduction in contamination with significant sustained reductions.

conclusionsChanging the method of blood culture collection from the commonly used nonsterile technique to a sterile process resulted in significant reductions in blood culture contamination at two community hospital EDs, including one with low baseline contamination. Monitoring the implementation process at both sites was important to identify and overcome operational challenges. At one study site, simplification of the process by removing the fenestrated drape component was a key for successful implementation.

Indexed as

Quality ImprovementAntisepsisBloodBlood Specimen CollectionChlorhexidineEmergency Service, HospitalHospitals, CommunityHumansChlorhexidine

Identifiers

PMID24628752
PMCPMC3984048

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.