ArticleSurgical endoscopy2014
Biomedical nanostructured coating for minimally invasive surgery devices applications: characterization, cell cytotoxicity evaluation and an animal study in rat.
Article in Surgical endoscopy, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 60 citations in OpenAlex.
- Article
- Microstructural and in-vitro characteristics of functional calcium silicate topcoat on hydroxyapatite coating for bio-implant applications.Progress in biomaterials · 2022Article
- Article
- Comparative healing of swine skin following incisions with different surgical devices.Annals of translational medicine · 2021Article
- Evaluation of Bone Wax Coated Bipolar Coagulation Forceps: Performance and Safety Assessment.Frontiers in surgery · 2021Article
- Biomimetic Anti-Adhesive Surface Microstructures on Electrosurgical Blade Fabricated by Long-Pulse Laser Inspired by Pangolin Scales.Micromachines · 2019Article
- Self-Lubricanting Slippery Surface with Wettability Gradients for Anti-Sticking of Electrosurgical Scalpel.Micromachines · 2018Article
- Effect of high-frequency electric field on the tissue sticking of minimally invasive electrosurgical devices.Royal Society open science · 2018Article
- Consistency and sealing of advanced bipolar tissue sealers.Medical devices (Auckland, N.Z.) · 2015Article
- An Immunomodulatory Protein (Ling Zhi-8) from a Ganoderma lucidum Induced Acceleration of Wound Healing in Rat Liver Tissues after Monopolar Electrosurgery.Evidence-based complementary and alternative medicine : eCAM · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThermal injury and tissue sticking, which influence wound remodeling, are major concerns in electrosurgery. In this study, the effect of lateral thermal injury caused by different electrosurgical electrodes on hepatic remodeling was investigated.
methodsA monopolar electrosurgical unit equipped with untreated stainless steel (SS) and chromium nitride coated stainless steel (CrN-SS) electrodes was used to create lesions on the liver lobes of adult rats. Animals were sacrificed for evaluations at 0, 3, 7, and 28 days postoperatively.
resultsCrN-SS needles generated lower levels of sticking tissue, and the thermographs showed that recorded highest temperature in liver tissue from the CrN-SS needle group was significantly lower than in the SS needle group. The total injury area of livers treated with CrN-SS needles was significantly lower than livers treated with SS needles at each time point. Moreover, the CrN-SS needles caused a relatively smaller area of lateral thermal injury, a smaller area of fibrotic tissue, and a faster process of hepatic remodeling in rat liver than the SS needles. Immunofluorescence staining and Western blot analysis showed that rats treated with CrN-SS needles expressed lower levels of NF-κB and caspase-3 postoperatively.
conclusionsThis study reveals that the plating of electrodes with a CrN film is an efficient method for improving the performance of electrosurgical units and should benefit wound remodeling. However, more tests must be performed to confirm these promising findings in human patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.