Evidence map›Paper›PMID 24617504›Full record

ArticleLangmuir : the ACS journal of surfaces and colloids2014

A high-sensitivity lanthanide nanoparticle reporter for mass cytometry: tests on microgels as a proxy for cells.

Wanjuan Lin, Yi Hou, Yijie Lu, Ahmed I Abdelrahman, Pengpeng Cao, Guangyao Zhao, Lemuel Tong, Jieshu Qian, Vladimir Baranov, Mark Nitz and 1 more

Abstract read
In one paragraph

Article in Langmuir : the ACS journal of surfaces and colloids, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Atomic mass tag of bismuth-209 for increasing the immunoassay multiplexing capacity of mass cytometry.Cytometry. Part A : the journal of the International Society for Analytical Cytology · 2017
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wanjuan LinDepartment of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario, Canada M5S 3H6.
Yi Hou
Yijie Lu
Ahmed I Abdelrahman
Pengpeng Cao
Guangyao Zhao
Lemuel Tong
Jieshu Qian
Vladimir Baranov
Mark Nitz
Mitchell A Winnik

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper addresses the question of whether one can use lanthanide nanoparticles (e.g., NaHoF4) to detect surface biomarkers expressed at low levels by mass cytometry. To avoid many of the complications of experiments on live or fixed cells, we carried out proof-of-concept experiments using aqueous microgels with a diameter on the order of 700 nm as a proxy for cells. These microgels were used to test whether nanoparticle (NP) reagents would allow the detection of as few as 100 proteins per "cell" in cell-by-cell assays. Streptavidin (SAv), which served as the model biomarker, was attached to the microgel in two different ways. Covalent coupling to surface carboxyls of the microgel led to large numbers (>10(4)) of proteins per microgel, whereas biotinylation of the microgel followed by exposure to SAv led to much smaller numbers of SAv per microgel. Using mass cytometry, we compared two biotin-containing reagents, which recognized and bound to the SAvs on the microgel. One was a metal chelating polymer (MCP), a biotin end-capped polyaspartamide containing 50 Tb(3+) ions per probe. The other was a biotinylated NaHoF4 NP containing 15 000 Ho atoms per probe. Nonspecific binding was determined with bovine serum albumin (BSA) conjugated microgels. The MCP was effective at detecting and quantifying SAvs on the microgel with covalently bound SAv (20 000 SAvs per microgel) but was unable to give a meaningful signal above that of the BSA-coated microgel for the samples with low levels of SAv. Here the NP reagent gave a signal 2 orders of magnitude stronger than that of the MCP and allowed detection of NPs ranging from 100 to 500 per microgel. Sensitivity was limited by the level of nonspecific adsorption. This proof of concept experiment demonstrates the enhanced sensitivity possible with NP reagents in cell-by-cell assays by mass cytometry.

Indexed as

AnimalsBiomimeticsBiotinCattleCytological TechniquesGelsLanthanoid Series ElementsNanoparticlesPolymersSerum Albumin, BovineStreptavidinBiotinGelsLanthanoid Series ElementsPolymersSerum Albumin, BovineStreptavidin

Identifiers

PMID24617504
PMCPMC3983384

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.