Evidence map›Paper›PMID 24608001›Full record

ArticleSensors (Basel, Switzerland)2014

DIMETER: a haptic master device for tremor diagnosis in neurodegenerative diseases.

Roberto González, Antonio Barrientos, Jaime del Cerro, Benito Coca

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Machine Learning for Differentiating Essential Tremor: A Scoping Review.Tremor and other hyperkinetic movements (New York, N.Y.) · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Roberto GonzálezCentre for Automation and Robotics UPM-CSIC, C/José Gutierrez Abascal 2, E-28006 Madrid, Spain. roberto.gonzalez@upm.es.
Antonio BarrientosCentre for Automation and Robotics UPM-CSIC, C/José Gutierrez Abascal 2, E-28006 Madrid, Spain. antonio.barrientos@upm.es.
Jaime del CerroCentre for Automation and Robotics UPM-CSIC, C/José Gutierrez Abascal 2, E-28006 Madrid, Spain. j.cerro@upm.es.
Benito CocaETSIDI-UPM, C/Ronda de Valencia 3, E-28012 Madrid, Spain. benitomaria.coca.hernandez@alumnos.upm.es.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, a device based on patient motion capture is developed for the reliable and non-invasive diagnosis of neurodegenerative diseases. The primary objective of this study is the classification of differential diagnosis between Parkinson's disease (PD) and essential tremor (ET). The DIMETER system has been used in the diagnoses of a significant number of patients at two medical centers in Spain. Research studies on classification have primarily focused on the use of well-known and reliable diagnosis criteria developed by qualified personnel. Here, we first present a literature review of the methods used to detect and evaluate tremor; then, we describe the DIMETER device in terms of the software and hardware used and the battery of tests developed to obtain the best diagnoses. All of the tests are classified and described in terms of the characteristics of the data obtained. A list of parameters obtained from the tests is provided, and the results obtained using multilayer perceptron (MLP) neural networks are presented and analyzed.

Indexed as

SoftwareTouchBiomechanical PhenomenaDiagnostic Techniques, NeurologicalHumansMovementNeural Networks, ComputerNeurodegenerative DiseasesPattern Recognition, AutomatedTremor

Identifiers

PMID24608001
PMCPMC4003956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.