ArticleMedical physics2014

X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

Steve Si Jia Feng, Carl J D'Orsi, Mary S Newell, Rebecca L Seidel, Bhavika Patel, Ioannis Sechopoulos

Abstract read
In one paragraph

Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Steve Si Jia FengDepartment of Biomedical Engineering, Georgia Institute of Technology and Emory University and Department of Radiology and Imaging Sciences, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.
Carl J D'OrsiDepartment of Radiology and Imaging Sciences, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.
Mary S NewellDepartment of Radiology and Imaging Sciences, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.
Rebecca L SeidelDepartment of Radiology and Imaging Sciences, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.
Bhavika PatelDepartment of Radiology and Imaging Sciences, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.
Ioannis SechopoulosDepartments of Radiology and Imaging Sciences, Hematology and Medical Oncology and Winship Cancer Institute, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322.

Funding

Image Quality Improvement and Breast Compression Reduction in Breast TomosynthesiR01CA163746 · NCI · RADBOUD UNIVERSITY NIJMEGEN MED CTR · PI SECHOPOULOS, IOANNIS · 2012 to 2015
$1.2M
NCI NIH HHS R01 CA163746NCI NIH HHS R01CA163746
6 · The paper itself

Abstract

purposeTo develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated.

methodsA previously developed model of compressed breast shapes undergoing mammography based on principal component analysis (PCA) was used to assemble 540 simulated breast volumes, of different shapes and sizes, undergoing DBT. A Monte Carlo (MC) simulation was used to generate the cranio-caudal (CC) view DBT x-ray scatter maps of these volumes, which were then assembled into a library. This library was incorporated into a previously developed software-based x-ray scatter correction, and the performance of this improved algorithm was evaluated with an observer study of 40 patient cases previously classified as BI-RADS® 4 or 5, evenly divided between mass and microcalcification cases. Observers were presented with both the original images and the scatter corrected (SC) images side by side and asked to indicate their preference, on a scale from -5 to +5, in terms of lesion conspicuity and quality of diagnostic features. Scores were normalized such that a negative score indicates a preference for the original images, and a positive score indicates a preference for the SC images.

resultsThe scatter map library removes the time-intensive MC simulation from the application of the scatter correction algorithm. While only one in four observers preferred the SC DBT images as a whole (combined mean score = 0.169 ± 0.37, p > 0.39), all observers exhibited a preference for the SC images when the lesion examined was a mass (1.06 ± 0.45, p < 0.0001). When the lesion examined consisted of microcalcification clusters, the observers exhibited a preference for the uncorrected images (-0.725 ± 0.51, p < 0.009).

conclusionsThe incorporation of the x-ray scatter map library into the scatter correction algorithm improves the efficiency of the algorithm. The observer study presented here is also the first test of the scatter correction algorithm with patient images and human observers, and demonstrates its potential to improve the clinical performance of DBT.

Indexed as

Scattering, RadiationAlgorithmsBreastBreast NeoplasmsFemaleHumansMammographyMonte Carlo MethodObserver VariationPrincipal Component AnalysisRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSoftwareX-Rays

Identifiers

PMID24593730
PMCPMC3978288

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.