ReviewDer Anaesthesist2014
[Mechanical resuscitation assist devices].
Review in Der Anaesthesist, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 13 citations in OpenAlex.
- [Future-oriented further development and approaches to "individualised" cardiopulmonary resuscitation].Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2025Review
- Computed Tomography Imaging in Simulated Ongoing Cardiopulmonary Resuscitation: No Need to Switch Off the Chest Compression Device during Image Acquisition.Diagnostics (Basel, Switzerland) · 2021Article
- Testing mechanical chest compression devices of different design for their suitability for prehospital patient transport - a simulator-based study.BMC emergency medicine · 2021Article
- Mechanical adjuncts for cardiocerebral resuscitation.Expert review of medical devices · 2019Review
- New Developments in Cardiac Arrest Management.Advances in anesthesia · 2016Article
- [Cardiac post-resuscitation care. An indication for trauma whole-body CT?].Der Unfallchirurg · 2016Article
- Mechanical chest compression: an alternative in helicopter emergency medical services?Internal and emergency medicine · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In Germany 100,000-160,000 people suffer from out-of-hospital cardiac arrest (OHCA) annually. The incidence of cardiopulmonary resuscitation (CPR) after OHCA varies between emergency ambulance services but is in the range of 30-90 CPR attempts per 100,000 inhabitants per year. Basic life support (BLS) involving chest compressions and ventilation is the key measure of resuscitation. Rapid initiation and quality of BLS are the most critical factors for CPR success. Even healthcare professionals are not always able to ensure the quality of CPR measures. Consequently in recent years mechanical resuscitation devices have been developed to optimize chest compression and the resulting circulation. In this article the mechanical resuscitation devices currently available in Germany are discussed and evaluated scientifically in context with available literature. The ANIMAX CPR device should not be used outside controlled trials as no clinical results have so far been published. The same applies to the new device Corpuls CPR which will be available on the market in early 2014. Based on the current published data a general recommendation for the routine use of LUCAS™ and AutoPulse® CPR cannot be given. The preliminary data of the CIRC trial and the published data of the LINC trial revealed that mechanical CPR is apparently equivalent to good manual CPR. For the final assessment further publications of large randomized studies must be analyzed (e.g. the CIRC and PaRAMeDIC trials). However, case control studies, case series and small studies have already shown that in special situations and in some cases patients will benefit from the automatic mechanical resuscitation devices (LUCAS™, AutoPulse®). This applies especially to emergency services where standard CPR quality is far below average and for patients who require prolonged CPR under difficult circumstances. This might be true in cases of resuscitation due to hypothermia, intoxication and pulmonary embolism as well as for patients requiring transport or coronary intervention when cardiac arrest persists. Three prospective randomized studies and the resulting meta-analysis are available for active compression-decompression resuscitation (ACD-CPR) in combination with an impedance threshold device (ITD). These studies compared ACD-ITD-CPR to standard CPR and clearly demonstrated that ACD-ITD-CPR is superior to standard CPR concerning short and long-term survival with good neurological recovery after OHCA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.