ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2014
Cell membrane deformation induced by a fibronectin-coated polystyrene microbead in a 200-MHz acoustic trap.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 32 citations in OpenAlex.
- Focused ultrasound for cellular mechanoactivation and nanomedicine delivery in cancer.Biomedical microdevices · 2026Review
- A Review of Single-Cell Microrobots: Classification, Driving Methods and Applications.Micromachines · 2023Review
- Manipulation and Mechanical Deformation of Leukemia Cells by High-Frequency Ultrasound Single Beam.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022Article
- Article
- Article
- Experimental study of the difference in deformation between normal and pathological, renal and bladder, cells induced by acoustic radiation force.European biophysics journal : EBJ · 2020Article
- Investigation of cell mechanics using single-beam acoustic tweezers as a versatile tool for the diagnosis and treatment of highly invasive breast cancer cell lines: an in vitro study.Microsystems & nanoengineering · 2020Article
- Characterizing Deformability of Drug Resistant Patient-Derived Acute Lymphoblastic Leukemia (ALL) Cells Using Acoustic Tweezers.Scientific reports · 2018Article
- Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement.Sensors (Basel, Switzerland) · 2018Article
- An adjustable multi-scale single beam acoustic tweezers based on ultrahigh frequency ultrasonic transducer.Biotechnology and bioengineering · 2017Article
- Quantification of Inter-Erythrocyte Forces with Ultra-High Frequency (410 MHz) Single Beam Acoustic Tweezer.Annals of biomedical engineering · 2017Article
- Microfluidics cell sample preparation for analysis: Advances in efficient cell enrichment and precise single cell capture.Biomicrofluidics · 2017Review
- Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing.Sensors (Basel, Switzerland) · 2016Article
- Cell Deformation by Single-beam Acoustic Trapping: A Promising Tool for Measurements of Cell Mechanics.Scientific reports · 2016Article
- Impedance matching network for high frequency ultrasonic transducer for cellular applications.Ultrasonics · 2016Article
- Acoustic tweezers for studying intracellular calcium signaling in SKBR-3 human breast cancer cells.Ultrasonics · 2015Article
- Advantages and Challenges of Relaxor-PbTiOProgress in materials science · 2015Article
- Non-contact multi-particle annular patterning and manipulation with ultrasound microbeam.Applied physics letters · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
Abstract
The measurement of cell mechanics is crucial for a better understanding of cellular responses during the progression of certain diseases and for the identification of the cell's nature. Many techniques using optical tweezers, atomic force microscopy, and micro-pipettes have been developed to probe and manipulate cells in the spatial domain. In particular, we recently proposed a two-dimensional acoustic trapping method as an alternative technique for small particle manipulation. Although the proposed method may have advantages over optical tweezers, its applications to cellular mechanics have not yet been vigorously investigated. This study represents an initial attempt to use acoustic tweezers as a tool in the field of cellular mechanics in which cancer cell membrane deformability is studied. A press-focused 193-MHz single-element lithium niobate (LiNbO3) transducer was designed and fabricated to trap a 5-μm polystyrene microbead near the ultrasound beam focus. The microbeads were coated with fibronectin, and trapped before being attached to the surface of a human breast cancer cell (MCF-7). The cell membrane was then stretched by remotely pulling a cell-attached microbead with the acoustic trap. The maximum cell membrane stretched lengths were measured to be 0.15, 0.54, and 1.41 μm at input voltages to the transducer of 6.3, 9.5, and 12.6 Vpp, respectively. The stretched length was found to increase nonlinearly as a function of the voltage input. No significant cytotoxicity was observed to result from the bead or the trapping force on the cell during or after the deformation procedure. Hence, the results convincingly demonstrated the possible application of the acoustic trapping technique as a tool for cell manipulation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.