Evidence map›Paper›PMID 24563157›Full record

ReviewSports medicine (Auckland, N.Z.)2014

A critical review of the history of low- to moderate-intensity steady-state VO2 kinetics.

Robert A Robergs

Abstract readHistorical ArticleReview
PubMed Publisher
In one paragraph

Review in Sports medicine (Auckland, N.Z.), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. A Hitchhiker's Guide to Physical and Cognitive Effort.Sports medicine (Auckland, N.Z.) · 2026
    Review
  3. Article
  4. Article
  5. Frontiers in physiology · 2025
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Concordance betweenPhysiological reports · 2019
    Article
  12. Article
  13. Review
  14. New Methods for Processing and Quantifying VOFrontiers in physiology · 2017
    Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Robert A RobergsSchool of Human Movement Studies, Charles Sturt University, Allen House, Building N1, 1:28 2:23, Bathurst, NSW, 2795, Australia, rrobergs@csu.edu.au.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Research into the rate of whole-body oxygen consumption (VO2) kinetics during exercise increments to low- to moderate-intensity steady-state exercise was originally based on the theory of linear first-order VO2 kinetics, implying that the VO2 response to steady-state exercise increments is a mono-exponential response of the same time constant (tau, τ) across all steady-state intensities. Despite the acceptance of this theory for more than 30 years, early research from the 1980s documented an increasing τ with increasing steady-state exercise intensity, and recent research has confirmed such results. Today, such evidence has led to retraction of the theory of linear first-order VO2 kinetics. This history, revealing the premature acceptance of a theory, and subsequent scientific investigation using improved research design, instrumentation and data processing, has important implications for the fragility of scientific theories and the need for continual testing of theories in the search for facts and not prematurely accepted constructs. This review provides historical evidence for a critical reappraisal of the theory of linear first-order VO2 kinetics and presents data to show the need for changes in the data-processing 'standards' of the discipline to improve measurement of instantaneous VO2 kinetics and the time to steady state. For example, to date, no study of VO2 kinetics has quantified and statistically analysed the time to steady state. Furthermore, the instability of τ across different exercise increments, and for the same increment from different baseline VO2 demand, prevents τ from being a valid measure of VO2 kinetics for different exercise conditions. The concept of quantifying kinetics from a total non-linear response, when no other field of kinetics pursues this methodology, also raises concern for the methods and models used to interpret steady-state VO2 kinetics.

Indexed as

Biomedical ResearchExerciseHistory, 20th CenturyHumansOxygen Consumption

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.