Evidence map›Paper›PMID 24562555›Full record

ArticleJournal of synchrotron radiation2014

D3, the new diffractometer for the macromolecular crystallography beamlines of the Swiss Light Source.

Martin R Fuchs, Claude Pradervand, Vincent Thominet, Roman Schneider, Ezequiel Panepucci, Marcel Grunder, Jose Gabadinho, Florian S N Dworkowski, Takashi Tomizaki, Jörg Schneider and 10 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Low-doseIUCrJ · 2020
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Martin R FuchsSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Claude PradervandSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Vincent ThominetSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Roman SchneiderSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Ezequiel PanepucciSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Marcel GrunderSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Jose GabadinhoSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Florian S N DworkowskiSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Takashi TomizakiSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Jörg SchneiderSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Aline MayerSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Adrian CurtinSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Vincent OliericSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Uli FrommherzSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Goran KotrleSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Jörg WelteSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Xinyu WangSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Stephan MaagSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.
Clemens Schulze-BrieseDECTRIS Ltd, Neuenhoferstrasse 107, 5400 Baden, Switzerland.
Meitian WangSwiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new diffractometer for microcrystallography has been developed for the three macromolecular crystallography beamlines of the Swiss Light Source. Building upon and critically extending previous developments realised for the high-resolution endstations of the two undulator beamlines X06SA and X10SA, as well as the super-bend dipole beamline X06DA, the new diffractometer was designed to the following core design goals. (i) Redesign of the goniometer to a sub-micrometer peak-to-peak cylinder of confusion for the horizontal single axis. Crystal sizes down to at least 5 µm and advanced sample-rastering and scanning modes are supported. In addition, it can accommodate the new multi-axis goniometer PRIGo (Parallel Robotics Inspired Goniometer). (ii) A rapid-change beam-shaping element system with aperture sizes down to a minimum of 10 µm for microcrystallography measurements. (iii) Integration of the on-axis microspectrophotometer MS3 for microscopic sample imaging with 1 µm image resolution. Its multi-mode optical spectroscopy module is always online and supports in situ UV/Vis absorption, fluorescence and Raman spectroscopy. (iv) High stability of the sample environment by a mineral cast support construction and by close containment of the cryo-stream. Further features are the support for in situ crystallization plate screening and a minimal achievable detector distance of 120 mm for the Pilatus 6M, 2M and the macromolecular crystallography group's planned future area detector Eiger 16M.

Indexed as

beamline endstationdiffractometermacromolecular crystallographymicrocrystallographymicrospectrophotometer

Identifiers

PMID24562555
PMCPMC3945418

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.