Evidence map›Paper›PMID 24558438›Full record

ArticlePloS one2014

Patient body weight-tailored contrast medium injection protocol for the craniocervical vessels: a prospective computed tomography study.

Rebecca Kessler, Katrin Hegenscheid, Steffen Fleck, Alexander Khaw, Michael Kirsch, Norbert Hosten, Sönke Langner

Abstract read
In one paragraph

Article in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rebecca KesslerInstitute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
Katrin HegenscheidInstitute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
Steffen FleckDepartment of Neurosurgery, University Medicine Greifswald, Greifswald, Germany.
Alexander KhawDepartment of Neurology, University Medicine Greifswald, Greifswald, Germany.
Michael KirschInstitute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
Norbert HostenInstitute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
Sönke LangnerInstitute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate body weight-tailored contrast medium (CM) administration for computed tomography angiography (CTA) of the craniocervical vessels.

methodsInstitutional review board approval was obtained, and all patients gave written informed consent. Sixty patients were consecutively assigned to one of three dose groups (20 patients per group) with CM doses of Visipaque 270® (iodixanol 270 mg/ml) tailored to body weight at doses of 1.5, 1.0, or 0.5 ml/kg. Region-of-interest (ROI) analysis of maximum enhancement (ME) was conducted, and signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated. Retrospective comparison was performed with three matched control groups examined with a standard CM dose (80 ml of Visipaque 270®). Image quality was rated by two neuroradiologists blinded to the CM dose used. Interrater reliability was calculated using kappa statistics.

resultsBody weight/BMI and ME were inversely correlated in the three control groups receiving the standard dose (r = -0.544/-0.597/-0.542/r = -0.358/r = -0.424/r = -0.280). Compared to standard dose, 1.5 ml/kg produced higher ME, SNR, and CNR in the anterior circulation (p≤0.038), 1.0 ml/kg had higher ME in cervical and medium-sized cerebral arteries (p≤0.034), and 0.5 ml/kg had lower ME, SNR and CNR for medium-sized cerebral arteries (p≤0.049). ME, SNR, and CNR were the same for 1.5 ml/kg and 1.0 ml/kg (p≥0.24), and both had higher values compared to 0.5 ml/kg (p≤0.043/p≤0.028). In patients with BMI>25, 1.5 ml/kg and 1.0 ml/kg produced higher ME than standard dose (p<0.001/p = 0.008), but ME in patients with BMI>25 did not differ between group 1 and group 2 (p = 0.673). In patients with BMI≤25, 1.5 ml/kg and 1.0 ml/kg produced ME comparable to standard dose (p = 0.132/p = 0.403). Regardless of patient weight, 0.5 ml/kg yielded lower ME than standard dose (p = 0.019/0.002).

conclusionsCraniocervical CTA with a body weight-tailored CM dose of 1.0 ml/kg (270 mg iodine/ml) reduces iodine load in patients weighing <80 kg while producing ME similar to standard dose and improves ME in patients with BMI>25.

Indexed as

Body WeightAgedAngiographyBody Mass IndexContrast MediaFemaleHumansInjectionsMaleMiddle AgedMiddle Cerebral ArteryNervous SystemPrecision MedicineProspective StudiesRadiation DosageSignal-To-Noise RatioContrast MediaiodixanolTriiodobenzoic Acids

Identifiers

PMID24558438
PMCPMC3928316

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.