The effect of design parameters of interspinous implants on kinematics and load bearing: an in vitro study.

Christoph Schilling, M Pfeiffer, T M Grupp, W Blömer, A Rohlmann

Open access · bronzeAbstract readComparative StudyEvaluation Study
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Influence of Deviated Centers of Rotation on Kinematics and Kinetics of a Lumbar Functional Spinal Unit: An In Vitro Study.Medical science monitor : international medical journal of experimental and clinical research · 2019
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Christoph SchillingAesculap AG, Research and Development, Am Aesculap Platz, 78532, Tuttlingen, Germany, christoph.schilling@aesculap.de.
M Pfeiffer
T M Grupp
W Blömer
A Rohlmann
Berlin Institute of Health at Charité - Universitätsmedizin Berlin · DELudwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA number of concepts with controversy approaches are currently discussed for interspinous stabilization (IPS). However, comparative biomechanical studies among the different systems are rare. Nevertheless, it remains unclear which biomechanical characteristics are influenced by different design features of these implants, such as implant stiffness or an additional tension band. Therefore, the aim of the present study was to compare different interspinous implants to investigate the biomechanical impact of IPS implant design on intersegmental kinematics, such as range of motion, neutral zone, center of rotation (COR), as well as load transfer like intradiscal pressure (IDP), to gain additional experience for clinical indications and limitations. MATERIAL AND

methodTwelve human lumbar spine specimens were tested in a spine loading apparatus. In vitro flexibility testing was performed by applying pure bending moments of 7.5 Nm without and with additional preload of 400 N in the three principal motion planes. Four interspinous implants, Coflex "COF" (Paradigm Spine, Germany), Wallis "WAL" (Abbott Laboratories, France), DIAM "DIA" (Sofamor Danek, France) and InterActiv (Aesculap AG, Germany) with two treatment options (without dorsal tensioning "IAO" and with dorsal tensioning "IAM") were consecutively tested in comparison to the native situation "NAT" and to a defect situation "DEF" of the functional spinal unit. The tested IPS devices are comprised of a compression stiffness range of 133 to 1,674 N/mm and a tensile stiffness range of 0-39 N/mm. Range of motion, neutral zone, center of rotation and intradiscal pressure were analyzed for all instrumentation steps and load cases.

conclusionFor the IPS, we found a correlation between compression stiffness and stabilization in extension. Here, the system with the lowest stiffness, DIA, displayed nearly no stabilization of the treated segment, whereas the system with the highest stiffness, WAL and COF, was most pronounced. This applies also for the correlation between device stiffness and IDP. In flexion only the degree of stabilization is in correlation with the tensile stiffness, whereas the IDP stays constant and is not affected by the different tensile stiffness. IPS is not able to stabilize in the frontal and transversal plane. Furthermore IPS does not substantially alter the location of the COR.

Indexed as

Prostheses and ImplantsProsthesis DesignAgedBiomechanical PhenomenaHumansLumbar VertebraeMiddle AgedOrthopedic ProceduresPliabilityRange of Motion, ArticularWeight-Bearing

Identifiers

PMID24549393
PMCPMC3960411
OpenAlexW2051543246

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.