Evidence map›Paper›PMID 24525900›Full record

ArticleNuclear medicine communications2014

Improving quantitative dosimetry in (177)Lu-DOTATATE SPECT by energy window-based scatter corrections.

Robin de Nijs, Vera Lagerburg, Thomas L Klausen, Søren Holm

Abstract read
In one paragraph

Article in Nuclear medicine communications, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed.

  1. Article
  2. Fast [EJNMMI physics · 2026
    Article
  3. Article
  4. Quantitative SPECT/CT: Technique and Clinical Applications.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2026
    Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Specific Uptake in the Bone Marrow Causes High Absorbed Red Marrow Doses During [Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023
    Article
  12. Towards accurateEJNMMI physics · 2023
    Article
  13. First experiences with dynamic renal [European journal of nuclear medicine and molecular imaging · 2022
    Article
  14. Reconstructed SPECT images ofScientific data · 2022
    Article
  15. [European journal of nuclear medicine and molecular imaging · 2022
    Article
  16. Article
  17. Article
  18. Article
  19. Journal of applied clinical medical physics · 2020
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Robin de NijsaDepartment of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark bDepartment of Clinical Physics, Spaarne Hospital, Hoofddorp cDepartment of Medical Physics, Catharina Hospital, Eindhoven, The Netherlands.
Vera Lagerburg
Thomas L Klausen
Søren Holm

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePatient-specific dosimetry of lutetium-177 ((177)Lu)-DOTATATE treatment in neuroendocrine tumours is important, because uptake differs across patients. Single photon emission computer tomography (SPECT)-based dosimetry requires a conversion factor between the obtained counts and the activity, which depends on the collimator type, the utilized energy windows and the applied scatter correction techniques. In this study, energy window subtraction-based scatter correction methods are compared experimentally and quantitatively. MATERIALS AND

methods(177)Lu SPECT images of a phantom with known activity concentration ratio between the uniform background and filled hollow spheres were acquired for three different collimators: low-energy high resolution (LEHR), low-energy general purpose (LEGP) and medium-energy general purpose (MEGP). Counts were collected in several energy windows, and scatter correction was performed by applying different methods such as effective scatter source estimation (ESSE), triple-energy and dual-energy window, double-photopeak window and downscatter correction. The intensity ratio between the spheres and the background was measured and corrected for the partial volume effect and used to compare the performance of the methods.

resultsLow-energy collimators combined with 208 keV energy windows give rise to artefacts. For the 113 keV energy window, large differences were observed in the ratios for the spheres. For MEGP collimators with the ESSE correction technique, the measured ratio was close to the real ratio, and the differences between spheres were small.

conclusionFor quantitative (177)Lu imaging MEGP collimators are advised. Both energy peaks can be utilized when the ESSE correction technique is applied. The difference between the calculated and the real ratio is less than 10% for both energy windows.

Indexed as

Organometallic CompoundsScattering, RadiationImage Processing, Computer-AssistedOctreotidePhantoms, ImagingRadiometryTomography, Emission-Computed, Single-Photonlutetium Lu 177 dotatateOctreotideOrganometallic Compounds

Identifiers

PMID24525900
PMCPMC3969156

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.