SynthesisKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2015
Fibrin sealant before wound closure in total knee arthroplasty reduced blood loss: a meta-analysis.
Synthesis in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 4 syntheses or guidelines pooled it, 26 citations in OpenAlex.
- Efficacy and safety of fibrin sealant application in patients undergoing thyroidectomy: a systematic review and meta-analysis.BMC surgery · 2024Pooled it
- A Systematic Review and Meta-analysis of the Topical Administration of Fibrin Sealant in Total Hip Arthroplasty.Scientific reports · 2018Pooled it
- Comparison of the effectiveness and safety of topical versus intravenous tranexamic acid in primary total knee arthroplasty: a meta-analysis of randomized controlled trials.Journal of orthopaedic surgery and research · 2017Pooled it
- The Efficacy of Bipolar Sealer on Blood Loss in Primary Total Hip Arthroplasty: A Meta-Analysis.Medicine · 2016Pooled it
- Effects of sealing the intramedullary femoral canal in total knee arthroplasty: A randomized study.Medicine · 2017Trial
- Prevention of postoperative anemia in hip hemiarthroplasty for femoral neck fractures: comparison between local haemostatic agents.Orthopedic reviews · 2022Article
- The association between bone mineral density and postoperative drainage volume following cruciate-substituting primary total knee arthroplasty: a cross-sectional study.Knee surgery & related research · 2021Article
- Perioperative Blood Management Strategies for Total Knee Arthroplasty.Orthopaedic surgery · 2018Review
- Factors that influence blood loss and need for transfusion following total knee arthroplasty.Annals of translational medicine · 2017Article
- The prevalence of depression in rheumatoid arthritis in China: A systematic review.Oncotarget · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFibrin sealant (FS) comprises a mixture of fibrinogen and thrombin that controls bleeding, reduces blood transfusions, improves tissue healing and shortens postoperative recovery time after various surgical procedures. However, no single study has been large enough to definitively determine whether fibrin sealant is safe and effective. We report a meta-analysis of randomized controlled trials (RCTs) evaluating the efficacy and safety of fibrin sealant in total knee arthroplasty.
methodsArticles published before August, 2012 were identified from PubMed, Embase, The Cochrane Library and other internet databases. Relevant journals and the recommendations of expert panels were also searched manually. We included only high-quality RCTs. Two independent reviewers searched and assessed the literature. Relevant data were analysed using RevMan 5.0.
resultsSeven RCTs met the inclusion criteria. Use of fibrin sealant significantly reduced haemoglobin decline mean difference (MD = -0.72), 95 % confidence interval [95 % CI (-0.83, -0.62), p < 0.00001], postoperative drainage volume [MD = -354.53, 95 % CI (-482.43, -226.63), p < 0.00001], the proportion of patients requiring blood transfusion risk differences [RD = -0.27, 95 % CI (-0.45, -0.08), p = 0.006] and the incidence of wound haematoma [RD = -0.11, 95 % CI (-0.22, -0.00), p = 0.04]. There were no significant differences in deep vein thrombosis, pulmonary embolism, infection rate or other complications between groups.
conclusionsUse of fibrin sealant in total knee arthroplasty was effective and safe, reduced haemoglobin decline, postoperative drainage volume, incidence of haematoma and need for blood transfusion, and did not increase the risk of complications. Due to the limited quality of the evidence currently available, more high-quality RCTs are required. LEVEL OF EVIDENCE: II.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.