Evidence map›Paper›PMID 24522269›Full record

ArticleJournal of radiation research2014

Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer.

Yuichi Akino, Indra J Das, Higinia R Cardenes, Colleen M Desrosiers

Abstract read
In one paragraph

Article in Journal of radiation research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT.Journal of applied clinical medical physics · 2025
    Guideline
  2. AAPM-RSS Medical Physics Practice Guideline 9.a. for SRS-SBRT.Journal of applied clinical medical physics · 2017
    Guideline
  3. Trial
  4. Article
  5. Article
  6. Histology, Tumor Volume, and Radiation Dose Predict Outcomes in NSCLC Patients After Stereotactic Ablative Radiotherapy.Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer · 2018
    Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yuichi AkinoDepartment of Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive RT 041, Indianapolis, IN 46202, USA yakino@iupui.edu.
Indra J DasDepartment of Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive RT 041, Indianapolis, IN 46202, USA.
Higinia R CardenesDepartment of Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive RT 041, Indianapolis, IN 46202, USA.
Colleen M DesrosiersDepartment of Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive RT 041, Indianapolis, IN 46202, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron transport. Under Institutional Review Board exemption status, 74 patients with lung cancer who were treated with SBRT were retrospectively evaluated. All treatment plans were generated using an anisotropic analytical algorithm (AAA) of an Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system. Two additional plans were created using the same treatment parameters (monitor units, beam angles and energy): a plan with no heterogeneity correction (NC), and a plan calculated with a pencil beam convolution algorithm (PBC). Compared with NC, AAA and PBC isocenter doses were on average 13.4% and 21.8% higher, respectively. The differences in the isocenter dose and the dose coverage for 95% of the PTV (D95%) between PBC and AAA were correlated logarithmically (ρ = 0.78 and ρ = 0.46, respectively) with PTV. Although D95% calculated with AAA was in general 2.9% larger than that for NC, patients with a small PTV showed a negative ΔD95% for AAA due to the significant effect of electron transport. The PTV volume shows logarithmic correlation with the effects of the lateral electron transport. These findings indicate that the dosimetric metrics and prescription, especially in clinical trials, should be clearly evaluated in the context of target volume characteristics and with proper heterogeneity correction.

Indexed as

AlgorithmsElectron TransportHumansLung NeoplasmsRadiometryRadiosurgeryRetrospective Studiesheterogeneity correctionslung cancerradiation dosimetrystereotactic body radiotherapy

Identifiers

PMID24522269
PMCPMC4099989

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.