Evidence map›Paper›PMID 24520952›Full record

ReviewBMC pulmonary medicine2014

Timing of noninvasive ventilation failure: causes, risk factors, and potential remedies.

Ezgi Ozyilmaz, Aylin Ozsancak Ugurlu, Stefano Nava

3 registry-linked trialsOpen access · goldAbstract readReview
In one paragraph

Review in BMC pulmonary medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 87 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
87citing papers in PubMed, 3 pooled it
12.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02352376 phase4completednot on this map

Effects of Non Invasive Ventilation on Heart Rate Variability After Coronary Bypass Grafting: Comparison Between Different Ventilator

TypeinterventionalSponsorFederal University of UberlandiaRan2013 to 2014Enrolled10ConditionsCoronary Artery BypassArmsConventional ventilator, Specific ventilator
NCT02894190 completednot on this mapstarted 2016, after this paper: background citation

Development and Validation of the Beliefs About Ventilation Questionnaire (BVQ)

TypeobservationalSponsorFondazione Don Carlo Gnocchi ETSRan2016 to 2020Enrolled250ConditionsChronic Respiratory Disease
NCT06257667 naunknown statusnot on this mapstarted 2024, after this paper: background citation

Randomized Controlled Trial to Investigate the Effect of High Flow Nasal Cannula Treatment on Carbon Dioxide-levels in COPD- Patients With Acute Hypercapnic Respiratory Failure, Using Either OptiflowTM or Optiflow+DuetTM Nasal Cannula

TypeinterventionalSponsorAalborg University HospitalRan2024 to 2026Enrolled138ConditionsHypercapnic Respiratory Failure, COPDArmsRespiratory Support
3 · Its place in the literature

Who cites it

87 citing papers in PubMed, 3 syntheses or guidelines pooled it, 269 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Influence of leaks and mask design on COBMJ open respiratory research · 2026
    Observational
  10. Review
  11. Article
  12. Article
  13. Observational
  14. Article
  15. Review
  16. The Prognostic Value of PaCOInternational journal of chronic obstructive pulmonary disease · 2026
    Article
  17. Review
  18. Observational
  19. Article
  20. Article

27 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Ezgi Ozyilmaz
Aylin Ozsancak Ugurlu
Stefano NavaDepartment of Specialistic, Diagnostic and Experimental Medicine (DIMES), Respiratory and Critical Care, University of Bologna, Sant'Orsola Malpighi Hospital building #15, Alma Mater Studiorum, via Massarenti n,15, Bologna 40185, Italy. stefanava@gmail.com.
Başkent University · TRCukurova University · TRUniversity of Bologna · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIdentifying the predictors of noninvasive ventilation (NIV) failure has attracted significant interest because of the strong link between failure and poor outcomes. However, very little attention has been paid to the timing of the failure. This narrative review focuses on the causes of NIV failure and risk factors and potential remedies for NIV failure, based on the timing factor.

resultsThe possible causes of immediate failure (within minutes to <1 h) are a weak cough reflex, excessive secretions, hypercapnic encephalopathy, intolerance, agitation, and patient-ventilator asynchrony. The major potential interventions include chest physiotherapeutic techniques, early fiberoptic bronchoscopy, changing ventilator settings, and judicious sedation. The risk factors for early failure (within 1 to 48 h) may differ for hypercapnic and hypoxemic respiratory failure. However, most cases of early failure are due to poor arterial blood gas (ABGs) and an inability to promptly correct them, increased severity of illness, and the persistence of a high respiratory rate. Despite a satisfactory initial response, late failure (48 h after NIV) can occur and may be related to sleep disturbance.

conclusionsEvery clinician dealing with NIV should be aware of these risk factors and the predicted parameters of NIV failure that may change during the application of NIV. Close monitoring is required to detect early and late signs of deterioration, thereby preventing unavoidable delays in intubation.

Indexed as

Noninvasive VentilationHumansPulmonary Disease, Chronic ObstructiveRisk FactorsTime FactorsTreatment Failure

Identifiers

PMID24520952
PMCPMC3925956
OpenAlexW2041987026

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.