Evidence map›Paper›PMID 24511215›Full record

ArticleJournal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems2013

A MEMS Dielectric Affinity Glucose Biosensor.

Xian Huang, Siqi Li, Erin Davis, Dachao Li, Qian Wang, Qiao Lin

Abstract read
In one paragraph

Article in Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. A hydrogel-based glucose affinity microsensor.Sensors and actuators. B, Chemical · 2016
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Xian HuangDepartment of Mechanical Engineering, Columbia University, New York, NY 10027 USA.
Siqi LiDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 USA.
Erin DavisDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 USA.
Dachao LiCollege of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Qian WangDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 USA.
Qiao LinDepartment of Mechanical Engineering, Columbia University, New York, NY 10027 USA.
University of South Carolina · USColumbia University · USTianjin University · CN

Funding

Translational Biomarker Analytical Core (TBAC)P30DK063608 · NIDDK · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI DOMENICO ACCILI · 2003 to 2026
$36.7M
NIDDK NIH HHS P30 DK063608
6 · The paper itself

Abstract

Continuous glucose monitoring (CGM) sensors based on affinity detection are desirable for long-term and stable glucose management. However, most affinity sensors contain mechanical moving structures and complex design in sensor actuation and signal readout, limiting their reliability in subcutaneously implantable glucose detection. We have previously demonstrated a proof-of-concept dielectric glucose sensor that measured pre-mixed glucose-sensitive polymer solutions at various glucose concentrations. This sensor features simplicity in sensor design, and possesses high specificity and accuracy in glucose detection. However, lack of glucose diffusion passage, this device is unable to fulfill real-time in-vivo monitoring. As a major improvement to this device, we present in this paper a fully implantable MEMS dielectric affinity glucose biosensor that contains a perforated electrode embedded in a suspended diaphragm. This capacitive-based sensor contains no moving parts, and enables glucose diffusion and real-time monitoring. The experimental results indicate that this sensor can detect glucose solutions at physiological concentrations and possesses good reversibility and reliability. This sensor has a time constant to glucose concentration change at approximately 3 min, which is comparable to commercial systems. The sensor has potential applications in fully implantable CGM that require excellent long-term stability and reliability.

Indexed as

affinity detectioncontinuous glucose monitoringDielectric biosensormicroelectromechanical systems technology

Identifiers

PMID24511215
PMCPMC3915936
OpenAlexW1984579334

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.