ArticleInternational journal of pharmaceutics2014
Development of high efficiency ventilation bag actuated dry powder inhalers.
Article in International journal of pharmaceutics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Rapid and Efficient Aerosol Delivery During 60 L/min High Flow Nasal Cannula Therapy-In Vitro Development of a Novel Dry Powder Delivery Platform.AAPS PharmSciTech · 2026Article
- Advancement of the Infant Air-Jet Dry Powder Inhaler (DPI): Evaluation of Different Positive-Pressure Air Sources and Flow Rates.Pharmaceutical research · 2021Article
- Administration of dry powders during respiratory supports.Annals of translational medicine · 2021Review
- Advancement of a Positive-Pressure Dry Powder Inhaler for Children: Use of a Vertical Aerosolization Chamber and Three-Dimensional Rod Array Interface.Pharmaceutical research · 2020Article
- Development of Dry Powder Inhaler Patient Interfaces for Improved Aerosol Delivery to Children.AAPS PharmSciTech · 2020Article
- Development of an Inline Dry Powder Inhaler for Oral or Trans-Nasal Aerosol Administration to Children.Journal of aerosol medicine and pulmonary drug delivery · 2020Article
- Optimizing Aerosolization Using Computational Fluid Dynamics in a Pediatric Air-Jet Dry Powder Inhaler.AAPS PharmSciTech · 2019Article
- Use of Computational Fluid Dynamics (CFD) Dispersion Parameters in the Development of a New DPI Actuated with Low Air Volumes.Pharmaceutical research · 2019Article
- Aerosol drug delivery to the lungs during nasal high flow therapy: an in vitro study.BMC pulmonary medicine · 2019Article
- Development of a New Inhaler for High-Efficiency Dispersion of Spray-Dried Powders Using Computational Fluid Dynamics (CFD) Modeling.The AAPS journal · 2019Article
- Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume.Pharmaceutical research · 2018Article
- Development of an Inline Dry Powder Inhaler That Requires Low Air Volume.Journal of aerosol medicine and pulmonary drug delivery · 2018Article
- Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy.International journal of pharmaceutics · 2018Article
- Aerosol Drug Delivery During Noninvasive Positive Pressure Ventilation: Effects of Intersubject Variability and Excipient Enhanced Growth.Journal of aerosol medicine and pulmonary drug delivery · 2017Article
- Efficient Nose-to-Lung (N2L) Aerosol Delivery with a Dry Powder Inhaler.Journal of aerosol medicine and pulmonary drug delivery · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
New active dry powder inhaler systems were developed and tested to efficiently aerosolize a carrier-free formulation. To assess inhaler performance, a challenging case study of aerosol lung delivery during high-flow nasal cannula (HFNC) therapy was selected. The active delivery system consisted of a ventilation bag for actuating the device, the DPI containing a flow control orifice and 3D rod array, and streamlined nasal cannula with separate inlets for the aerosol and HFNC therapy gas. In vitro experiments were conducted to assess deposition in the device, emitted dose (ED) from the nasal cannula, and powder deaggregation. The best performing systems achieved EDs of 70-80% with fine particle fractions <5 μm of 65-85% and mass median aerodynamic diameters of 1.5 μm, which were target conditions for controlled condensational growth aerosol delivery. Decreasing the size of the flow control orifice from 3.6 to 2.3mm reduced the flow rate through the system with manual bag actuations from an average of 35 to 15LPM, while improving ED and aerosolization performance. The new devices can be applied to improve aerosol delivery during mechanical ventilation, nose-to-lung aerosol administration, and to assist patients that cannot reproducibly use passive DPIs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.