Evidence map›Paper›PMID 24506630›Full record

ArticleMedical physics2014

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures.

Maryam E Rettmann, David R Holmes, David M Kwartowitz, Mia Gunawan, Susan B Johnson, Jon J Camp, Bruce M Cameron, Charles Dalegrave, Mark W Kolasa, Douglas L Packer and 1 more

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 2 countries.

Maryam E RettmannBiomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905.
David R HolmesBiomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905.
David M KwartowitzDepartment of Bioengineering, Clemson University, Clemson, South Carolina 29634.
Mia GunawanDepartment of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington D.C. 20057.
Susan B JohnsonDivision of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905.
Jon J CampBiomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905.
Bruce M CameronBiomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905.
Charles DalegraveClinical Cardiac Electrophysiology, Cardiology Division Hospital Sao Paulo, Federal University of Sao Paulo, 04024-002 Brazil.
Mark W KolasaDavid Grant Medical Center, Fairfield, California 94535.
Douglas L PackerDivision of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905.
Richard A RobbBiomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905.
Mayo Clinic · USClemson University · USGeorgetown University · USGrant Medical Center · USHospital São Paulo · BR

Funding

5-D Image Guided Cardiac Ablation TherapyR01EB002834 · NIBIB · MAYO CLINIC ROCHESTER · PI ROBB, RICHARD A · 2003 to 2012
$3.9M
NIBIB NIH HHS R01 EB002834NIBIB NIH HHS R01EB002834
6 · The paper itself

Abstract

purposeIn cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated.

methodsData from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamic in vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only.

resultsThe phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone.

conclusionsIn this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

Indexed as

Models, AnatomicPreoperative PeriodAlgorithmsAnimalsCatheter AblationDogsHeart AtriaHumansMonte Carlo MethodPhantoms, ImagingPrecision Medicine

Identifiers

PMID24506630
PMCPMC3977909
OpenAlexW1985188644

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.