ArticleHeart and vessels2015
Brachial artery diameter has a predictive value in the improvement of flow-mediated dilation after aortic valve replacement for aortic stenosis.
Article in Heart and vessels, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 15 citations in OpenAlex.
- Improved Endothelial and Autonomic Function after Transcatheter Aortic Valve Implantation.Reviews in cardiovascular medicine · 2023Article
- Patients with volume-loaded right ventricle - quantification of left ventricular hemodynamic response to intervention measured by noninvasive pressure-volume loops.Frontiers in physiology · 2023Article
- Improvement in Vascular Endothelial Function following Transcatheter Aortic Valve Implantation.Medicina (Kaunas, Lithuania) · 2021Article
- Atrial septal defect and patent foramen ovale: early and long-term effects on endothelial function after percutaneous occlusion procedure.Heart and vessels · 2019Article
- Assessment of vascular autonomic function using peripheral arterial tonometry.Heart and vessels · 2017Article
- Circulating matrix metalloproteinase patterns in association with aortic dilatation in bicuspid aortic valve patients with isolated severe aortic stenosis.Heart and vessels · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aortic stenosis (AS) is the most common valvular disease and aortic valve replacement (AVR) is one of its most effective interventions. AS affects not only the left ventricle, but also vascular function beyond the stenotic valve, which can lead to various types of vascular dysfunction. However, research evaluating the effect of AS on aortic vascular function is limited. In this study, we investigated clinical meaning to evaluate endothelial function in subjects with AS. From April 2011 to April 2012, 20 consecutive adult patients with degenerative AS (mean age, 74.7 ± 7.4 years; range 50-83 years) who underwent AVR at our institution were included in the study. We measured flow-mediated dilation (FMD) to evaluate the effect of AS on endothelial function. The difference between brachial artery diameter (BAD) before (4.0 ± 0.7 mm) and after AVR (3.9 ± 0.6 mm) was not significant (p = 0.043), but FMD significantly improved after AVR (from 3.1 ± 1.8 to 6.0 ± 2.7 %, p < 0.0001). We also analyzed FMD × BAD index, endogenous vasodilatory capability independent of BAD, resulting that it also significantly increased after AVR (12.3 ± 7.0-22.5 ± 9.3, p < 0.0001). We divided patients into two groups by pre- to post-AVR change in FMD (ΔFMD); large-ΔFMD group [ΔFMD >3.0 % (median value)] and small-ΔFMD group (ΔFMD <3.0 %). There were no significant changes in age, blood pressure, heart rate, B-type natriuretic peptide, or echocardiographic parameters in either group. In contrast, BAD was significantly larger in the small ΔFMD group (4.3 ± 0.7 mm) than in the large ΔFMD group (3.7 ± 0.7 mm) (p = 0.030). In addition, cardio-thoracic ratio was significantly greater in the small ΔFMD group (58.4 ± 7.1 %) than in the large ΔFMD group (53.7 ± 4.6 %) (p = 0.048). Receiver operating characteristic curve analysis of BAD to differentiate large and small ΔFMD demonstrated an area under the curve of 0.750 (p = 0.059) and that optimal cutoff for BAD was 4.28 mm (70 % sensitivity, 80 % specificity). AVR in subjects with AS is associated with a significant improvement in FMD in the brachial artery. Measurement of the BAD may be helpful in distinguishing whether the impairment of FMD in AS derives from a stenotic valve or vascular remodeling.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.