ArticleHeart and vessels2015
Multi-modality imaging for stent edge assessment.
Article in Heart and vessels, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Optical coherence tomography (OCT) has a sufficiently high resolution to allow assessment of stent edge dissection (ED). The aims of the present study were as follows: (1) evaluation of the frequency of stent ED using OCT; (2) comparison of stent ED detection rates obtained using angiography, intravascular ultrasound (IVUS), and OCT; and (3) IVUS-Virtual Histology (IVUS-VH) evaluation of plaque composition at the site of stent EDs detected by OCT after percutaneous coronary intervention (PCI). Fifty-eight consecutive patients (59 lesions, 100 stent edges) who underwent balloon-expandable stent implantation and post-stent assessment with OCT and IVUS-VH were included. OCT revealed stent ED in 24.0 % (24 of 100) of stent edges after PCI with a balloon-expandable stent. In contrast, ED was detected in only 3.0 % (3 of 100) of stent edges using angiography and 4.0 % (4 of 100) of stent edges using IVUS. Plaque evaluation using IVUS-VH showed that the percent necrotic core (21.2 ± 8.3 vs. 13.4 ± 10.7 %, p = 0.001) and absolute dense calcium (2.9 ± 2.4 vs. 1.3 ± 2.2 mm(3), p = 0.0104) and dense calcium (13.8 ± 9.3 vs. 5.4 ± 5.8 %, p < 0.001) volumes were greater in the ED group than in the non-ED group. Thus, OCT is superior to conventional coronary angiography and IVUS in the identification of stent ED. In addition, the plaque composition at the ED site is characterized by a necrotic core and greater dense calcium levels than those observed at the non-ED site.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials