Evidence map›Paper›PMID 24474759›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2014

Near-infrared-actuated devices for remotely controlled drug delivery.

Brian P Timko, Manuel Arruebo, Sahadev A Shankarappa, J Brian McAlvin, Obiajulu S Okonkwo, Boaz Mizrahi, Cristina F Stefanescu, Leyre Gomez, Jia Zhu, Angela Zhu and 3 more

Open access · bronzeAbstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 67 papers.

0numbers the graph read from it
0cells of the map it votes in
67citing papers in PubMed
16.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

67 citing papers in PubMed, 200 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Externally triggered drug delivery systems.Smart materials in medicine · 2024
    Article
  7. Review
  8. Article
  9. Engineered exosomes from different sources for cancer-targeted therapy.Signal transduction and targeted therapy · 2023
    Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. Review
  15. Article
  16. Article
  17. Review
  18. Recent Advances in Insulin Therapy.Diabetes technology & therapeutics · 2020
    Review
  19. Stimuli-Responsive Insulin Delivery Devices.Pharmaceutical research · 2020
    Review
  20. Article

7 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 3 countries.

Brian P TimkoLaboratory for Biomaterials and Drug Delivery, Department of Anesthesiology, Division of Critical Care Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115.
Manuel Arruebo
Sahadev A Shankarappa
J Brian McAlvin
Obiajulu S Okonkwo
Boaz Mizrahi
Cristina F Stefanescu
Leyre Gomez
Jia Zhu
Angela Zhu
Jesus Santamaria
Robert Langer
Daniel S Kohane
Massachusetts Institute of Technology · USHarvard University · USUniversidad de Zaragoza · ESAmrita Institute of Medical Sciences and Research Centre · INBoston Children's Hospital · USInstituto de Nanociencia y Materiales de Aragón · ES

Funding

Prolonged Duration Local AnesthesiaR01GM073626 · NIGMS · MASSACHUSETTS GENERAL HOSPITAL · PI KOHANE, DANIEL S · 2006 to 2018
$4.7M
A Photo-triggered on-demand drug delivery system for chronic painF32GM096546 · NIGMS · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI TIMKO, BRIAN PAUL · 2011 to 2012
$101k
NIGMS NIH HHS F32 GM096546NIGMS NIH HHS F32GM096546NIGMS NIH HHS GM073626NIGMS NIH HHS R01 GM073626
6 · The paper itself

Abstract

A reservoir that could be remotely triggered to release a drug would enable the patient or physician to achieve on-demand, reproducible, repeated, and tunable dosing. Such a device would allow precise adjustment of dosage to desired effect, with a consequent minimization of toxicity, and could obviate repeated drug administrations or device implantations, enhancing patient compliance. It should exhibit low off-state leakage to minimize basal effects, and tunable on-state release profiles that could be adjusted from pulsatile to sustained in real time. Despite the clear clinical need for a device that meets these criteria, none has been reported to date to our knowledge. To address this deficiency, we developed an implantable reservoir capped by a nanocomposite membrane whose permeability was modulated by irradiation with a near-infrared laser. Irradiated devices could exhibit sustained on-state drug release for at least 3 h, and could reproducibly deliver short pulses over at least 10 cycles, with an on/off ratio of 30. Devices containing aspart, a fast-acting insulin analog, could achieve glycemic control after s.c. implantation in diabetic rats, with reproducible dosing controlled by the intensity and timing of irradiation over a 2-wk period. These devices can be loaded with a wide range of drug types, and therefore represent a platform technology that might be used to address a wide variety of clinical indications.

Indexed as

Drug Delivery SystemsInfrared RaysAnimalsEquipment DesignMicroscopy, Electron, TransmissionNanocompositesRatsRats, Sprague-DawleyReproducibility of Resultsdiabetesethylcellulosegoldnanoshellpoly(n-isopropylacrylamide)

Identifiers

PMID24474759
PMCPMC3910641
OpenAlexW2166349229

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.