Evidence map›Paper›PMID 24470535›Full record

ArticleThe Annals of occupational hygiene2014

Collection efficiencies of high flow rate personal respirable samplers when measuring Arizona road dust and analysis of quartz by x-ray diffraction.

Peter Stacey, Taekhee Lee, Andrew Thorpe, Paul Roberts, Gillian Frost, Martin Harper

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in The Annals of occupational hygiene, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 22 citations in OpenAlex.

  1. Influence of COAntibiotics (Basel, Switzerland) · 2024
    Article
  2. Article
  3. Review
  4. A novel sampling cassette for field-based analysis of respirable crystalline silica.Journal of occupational and environmental hygiene · 2021
    Article
  5. Occupational Exposure and Environmental Release: The Case Study of Pouring TiOInternational journal of environmental research and public health · 2021
    Article
  6. Laboratory comparison of new high flow rate respirable size-selective sampler.Journal of occupational and environmental hygiene · 2018
    Article
  7. Particle release and control of worker exposure during laboratory-scale synthesis, handling and simulated spills of manufactured nanomaterials in fume hoods.Journal of nanoparticle research : an interdisciplinary forum for nanoscale science and technology · 2018
    Article
  8. Article
  9. Article
  10. Article
  11. Calibration of high flow rate thoracic-size selective samplers.Journal of occupational and environmental hygiene · 2016
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Peter Stacey1. Analytical Sciences Unit, Health and Safety Laboratory, Harpur Hill, Buxton SK17 9JN, UK;
Taekhee Lee
Andrew Thorpe
Paul Roberts
Gillian Frost
Martin Harper
Health & Safety Laboratory · GBNational Institute for Occupational Safety and Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prolonged exposure to respirable crystalline silica (RCS) causes silicosis and is also considered a cause of cancer. To meet emerging needs for precise measurements of RCS, from shorter sampling periods (<4 h) and lower air concentrations, collaborative work was done to assess the differences between personal respirable samplers at higher flow rates. The performance of FSP10, GK2.69, and CIP 10 R samplers were compared with that of the Safety In Mines Personal Dust Sampler (SIMPEDS) sampler as a reference, which is commonly used in the UK for the measurement of RCS. In addition, the performance of the FSP10 and GK 2.69 samplers were compared; at the nominal flow rates recommended by the manufacturers of 10 and 4.2 l · min(-1) and with flow rates proposed by the National Institute for Occupational Safety and Health of 11.2 and 4.4 l · min(-1). Samplers were exposed to aerosols of ultrafine and medium grades of Arizona road dust (ARD) generated in a calm air chamber. All analyses for RCS in this study were performed at the Health and Safety Laboratory. The difference in flow rates for the GK2.69 is small and does not result in a substantial difference in collection efficiency for the dusts tested, while the performance of the FSP10 at 11.2 l · min(-1) was more comparable with samples from the SIMPEDS. Conversely, the GK2.69 collected proportionately more crystalline silica in the respirable dust than other samplers, which then produced RCS results most comparable with the SIMPEDS. The CIP 10 R collected less ultrafine ARD than other samplers, as might be expected based on earlier performance evaluations. The higher flow rate for the FSP10 should be an added advantage for task-specific sampling or when measuring air concentrations less than current occupational exposure limits.

Indexed as

X-Ray DiffractionAerosolsAir PollutantsArizonaDustEnvironmental MonitoringHumansInhalation ExposureParticle SizeSilicon DioxideAerosolsAir PollutantsDustSilicon DioxideArizona road dustCIP 10 RFSP10GK2.69quartzrespirablesamplersilicaSIMPEDSx-ray diffractionXRD

Identifiers

PMID24470535
PMCPMC3979280
OpenAlexW2160057907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.