Evidence map›Paper›PMID 24468390›Full record

ArticleTalanta2014

Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.

Amr Addeck, Kim Croes, Kersten Van Langenhove, Michael S Denison, Ahmed S Afify, Yue Gao, Marc Elskens, Willy Baeyens

Abstract read
In one paragraph

Article in Talanta, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Amr AddeckDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium.
Kim CroesDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium. Electronic address: kim.croes@vub.ac.be.
Kersten Van LangenhoveDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium.
Michael S DenisonDepartment of Environmental Toxicology, University of California at Davis, Davis, CA 95616, USA.
Ahmed S AfifyDepartment of Applied Science and Technology, University of Politecnico di Torino, Turin, TO 10129, Italy.
Yue GaoDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium.
Marc ElskensDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium.
Willy BaeyensDepartment of Analytical and Environmental Chemistry, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium.

Funding

Workshop on Environmental Technology Transfer and EntrepreneurshipP42ES004699 · NIEHS · UNIVERSITY OF CALIFORNIA DAVIS · PI VASYLIEVA, NATALIA · 1987 to 2021
$50.1M
NIEHS NIH HHS ES04699NIEHS NIH HHS P42 ES004699
6 · The paper itself

Abstract

Ceramic passive samplers or toximeters (packed with active carbon 1%, w/w, on celite), in combination with the CALUX bioassay have been used as a time-integrated monitoring technique for dissolved dioxin-like PCBs in urban and industrial wastewaters. The technique showed to be reliable during laboratory experiments: (1) PCB-126 amounts extracted from the passive samplers increased linearly with the time of exposure and (2) PCB-126 concentrations calculated from the amounts accumulated by the passive samplers were in agreement with their concentrations in the testing solution. Afterwards the toximeters were applied in the field. Two sampling sites located in Egypt were chosen: the Belbeis drainage canal, and the EMAK paper mill. A total of 18 ceramic toximeters were exposed to the wastewater in both sampling sites for a maximum period of 4 weeks. Two samplers were collected weekly from each site to monitor the increase in target analytes over time. Extracts were analyzed using the CALUX bioassay and the total dioxin-like PCB toxicity was reported for the aqueous phase (water column), as well as the solid phase (sediment and sludge) in both sampling sites. The time-weighted average concentration (TWA) of dl-PCBs in wastewater of the paper mill during the sampling period ranged between 7.1 and 9.1 pg-BEQL(-1), while that of the drainage canal ranged between 9.5 and 12.2 pg-BEQL(-1). The dl-PCBs in the fibrous sludge (paper mill) and bottom sediment (drainage canal) were 0.5 and 0.4 pg-BEQg(-1) dry-weight, respectively. The organic-carbon normalized partition coefficients between sediment and water (logKoc) for the paper mill and the canal were 2.4 and 4.3, respectively.

Indexed as

CeramicsDioxinsEnvironmental MonitoringEquipment DesignPolychlorinated BiphenylsWastewater3,4,5,3',4'-pentachlorobiphenylDioxinsPolychlorinated BiphenylsWastewaterCALUX bioassayCeramic toximeterDioxin-like PCBsDistribution coefficientPassive samplingWastewater monitoring

Identifiers

PMID24468390
PMCPMC4379351

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.