ArticleBiomedical optics express2013

In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor.

Songlin Yu, Dachao Li, Hao Chong, Changyue Sun, Haixia Yu, Kexin Xu

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
7.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Songlin YuState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Dachao LiState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Hao ChongState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Changyue SunTianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Haixia YuTianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Kexin XuState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
Tianjin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Because mid-infrared (mid-IR) spectroscopy is not a promising method to noninvasively measure glucose in vivo, a method for minimally invasive high-precision glucose determination in vivo by mid-IR laser spectroscopy combined with a tunable laser source and small fiber-optic attenuated total reflection (ATR) sensor is introduced. The potential of this method was evaluated in vitro. This research presents a mid-infrared tunable laser with a broad emission spectrum band of 9.19 to 9.77[Formula: see text](1024~1088 cm(-1)) and proposes a method to control and stabilize the laser emission wavelength and power. Moreover, several fiber-optic ATR sensors were fabricated and investigated to determine glucose in combination with the tunable laser source, and the effective sensing optical length of these sensors was determined for the first time. In addition, the sensitivity of this system was four times that of a Fourier transform infrared (FT-IR) spectrometer. The noise-equivalent concentration (NEC) of this laser measurement system was as low as 3.8 mg/dL, which is among the most precise glucose measurements using mid-infrared spectroscopy. Furthermore, a partial least-squares regression and Clarke error grid were used to quantify the predictability and evaluate the prediction accuracy of glucose concentration in the range of 5 to 500 mg/dL (physiologically relevant range: 30~400 mg/dL). The experimental results were clinically acceptable. The high sensitivity, tunable laser source, low NEC and small fiber-optic ATR sensor demonstrate an encouraging step in the work towards precisely monitoring glucose levels in vivo.

Indexed as

(170.1470) Blood or tissue constituent monitoring(300.1030) Absorption(300.6340) Spectroscopy, infrared

Identifiers

PMID24466493
PMCPMC3891338
OpenAlexW2049580756

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.