Evidence map›Paper›PMID 24443202›Full record

ArticleMagnetic resonance in medicine2014

Microstructural origins of gadolinium-enhanced susceptibility contrast and anisotropy.

Russell Dibb, Wei Li, Gary Cofer, Chunlei Liu

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
3.2field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Asymmetric susceptibility tensor imaging.Magnetic resonance in medicine · 2021
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Magnetic susceptibility anisotropy of myocardium imaged by cardiovascular magnetic resonance reflects the anisotropy of myocardial filament α-helix polypeptide bonds.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2015
    Article
  14. Review
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Russell DibbCenter for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina, USA; Biomedical Engineering, Duke University, Durham, North Carolina, USA.
Wei Li
Gary Cofer
Chunlei Liu
Duke Medical Center · USDuke University · USDuke University Hospital · US

Funding

INTEGRATED CENTER FOR IN VIVO MICROSCOPYP41EB015897 · NIBIB · DUKE UNIVERSITY · PI JOHNSON, GEORGE ALLAN · 2012 to 2017
$7.4M
Training in Medical ImagingT32EB001040 · NIBIB · DUKE UNIVERSITY · PI NIGHTINGALE, KATHRYN RADABAUGH · 2003 to 2018
$4.4M
Ultra-Resolution Imaging of Brain Circuitry and its Development in Mental HealthR01MH096979 · NIMH · UNIVERSITY OF CALIFORNIA BERKELEY · PI LIU, CHUNLEI · 2013 to 2017
$1.8M
NIBIB NIH HHS P41 EB015897NIBIB NIH HHS T32 EB001040NIMH NIH HHS MH096979NIMH NIH HHS R01 MH096979
6 · The paper itself

Abstract

purposeMR histology based on magnetic susceptibility can be used to visualize diamagnetic myelin (and its deterioration) in the central nervous system and is facilitated by the application of high magnetic field strengths and paramagnetic contrast agents. Characterizing the effect of these tools will aid in assessing white matter myelin content and microstructure.

methodsImage data from six gadolinium-perfused mouse brain specimens were acquired at 2.0, 7.0, and 9.4 Tesla. Magnetic susceptibility contrast was analyzed for its dependence on field strength, gadolinium concentration, and white matter fiber orientation. A model for this contrast is presented based on the three-pool model for white matter.

resultsThe specimen data illustrate that white-gray matter susceptibility contrast is field strength independent. White-gray matter contrast improves significantly as a function of gadolinium contrast agent in the tissue, i.e., white matter appears increasingly more diamagnetic relative to gray matter. The simulated data from the model suggest that susceptibility anisotropy of white matter fiber bundles increases nonlinearly as a function of gadolinium concentration due to contrast agent compartmentalization into the extracellular white matter water pool.

conclusionUsing contrast agents in MR histology facilitates white-gray matter susceptibility contrast modulation and the probing of white matter microstructure and orientation.

Indexed as

AnimalsAnisotropyBrainContrast MediaDiffusion Tensor ImagingDose-Response Relationship, DrugGadoliniumGray MatterHeterocyclic CompoundsMaleMiceMice, Inbred C57BLOrganometallic CompoundsReproducibility of ResultsSensitivity and SpecificityWhite MatterContrast MediaGadoliniumgadoteridolHeterocyclic CompoundsOrganometallic Compoundsanisotropic magnetic susceptibilitynonlinear contrast enhancementquantitative susceptibility mappingresonance frequency shifttissue compartmentalizationwhite matter

Identifiers

PMID24443202
PMCPMC4102673
OpenAlexW1758556346

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked