Lateral and axial measurement differences between spectral-domain optical coherence tomography systems.

Francisco A Folgar, Eric L Yuan, Sina Farsiu, Cynthia A Toth

Erratum issued Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Journal of biomedical optics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT01588041 (Intraoperative OCT Guidance of Intraocular Surgery), which is not on this map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01588041 completednot on this map

Intraoperative OCT Guidance of Intraocular Surgery

TypeobservationalSponsorDuke UniversityRan2009 to 2018Enrolled269ConditionsEye Manifestations
3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 32 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Subclinical Retinal versus Brain Findings in Infants with Hypoxic Ischemic Encephalopathy.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2020
    Article
  12. [RPE morphometry in geographic atrophy due to AMD].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2019
    Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2015
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Francisco A FolgarDuke University, Department of Ophthalmology, Durham, North Carolina 27710.
Eric L YuanDuke University, Department of Ophthalmology, Durham, North Carolina 27710.
Sina FarsiuDuke University, Department of Ophthalmology, Durham, North Carolina 27710 bDuke University, Department of Biomedical Engineering, Durham, North Carolina 27710.
Cynthia A TothDuke University, Department of Ophthalmology, Durham, North Carolina 27710 bDuke University, Department of Biomedical Engineering, Durham, North Carolina 27710.
Duke University · US

Funding

Intraoperative OCT Guidance of Intraocular SurgeryR01EY023039 · NEI · DUKE UNIVERSITY · PI IZATT, JOSEPH A, TOTH, CYNTHIA ANN · 2013 to 2016
$3.9M
NEI NIH HHS R01 EY023039
6 · The paper itself

Abstract

We assessed the reproducibility of lateral and axial measurements performed with spectral-domain optical coherence tomography (SDOCT) instruments from a single manufacturer and across several manufacturers. One human retina phantom was imaged on two instruments each from four SDOCT platforms: Zeiss Cirrus, Heidelberg Spectralis, Bioptigen SDOIS, and hand-held Bioptigen Envisu. Built-in software calipers were used to perform manual measurements of a fixed lateral width (LW), central foveal thickness (CFT), and parafoveal thickness (PFT) 1 mm from foveal center. Inter- and intraplatform reproducibilities were assessed with analysis of variance and Tukey-Kramer tests. The range of measurements between platforms was 5171 to 5290 μm for mean LW (p<0.001), 162 to 196 μm for mean CFT (p<0.001), and 267 to 316 μm for mean PFT (p<0.001). All SDOCT platforms had significant differences between each other for all measurements, except LW between Bioptigen SDOIS and Envisu (p=0.27). Intraplatform differences were significantly smaller than interplatform differences for LW (p=0.020), CFT (p=0.045), and PFT (p=0.004). Conversion factors were generated for lateral and axial scaling between SDOCT platforms. Lateral and axial manual measurements have greater variance across different SDOCT platforms than between instruments from the same platform. Conversion factors for measurements from different platforms can produce normalized values for patient care and clinical studies.

Indexed as

AutomationEquipment DesignEyeFovea CentralisHumansOptics and PhotonicsPhantoms, ImagingReproducibility of ResultsRetinaScattering, RadiationSoftwareTomography, Optical Coherence

Identifiers

PMID24441877
PMCPMC3894429
OpenAlexW4252461477

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.