Evidence map›Paper›PMID 24439406›Full record

ArticleBiomaterials2014

Systemic oxygen delivery by peritoneal perfusion of oxygen microbubbles.

Jameel A Feshitan, Nathan D Legband, Mark A Borden, Benjamin S Terry

Abstract read
In one paragraph

Article in Biomaterials, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 72 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Colonic oxygen microbubbles augment systemic oxygenation and COIntensive care medicine experimental · 2023
    Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Magnetic resonance imaging of oxygen microbubbles.Healthcare technology letters · 2019
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Jameel A FeshitanDepartment of Mechanical Engineering, Materials Science and Engineering Program, University of Colorado, Boulder, CO 80309, USA.
Nathan D LegbandDepartment of Mechanical and Materials Engineering, University of Nebraska, Lincoln, NE 68588, USA.
Mark A BordenDepartment of Mechanical Engineering, Materials Science and Engineering Program, University of Colorado, Boulder, CO 80309, USA. Electronic address: mark.borden@colorado.edu.
Benjamin S TerryDepartment of Mechanical and Materials Engineering, University of Nebraska, Lincoln, NE 68588, USA. Electronic address: bterry2@unl.edu.
University of Colorado Boulder · USUniversity of Nebraska–Lincoln · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Severe hypoxemia refractory to pulmonary mechanical ventilation remains life-threatening in critically ill patients. Peritoneal ventilation has long been desired for extrapulmonary oxygenation owing to easy access of the peritoneal cavity for catheterization and the relative safety compared to an extracorporeal circuit. Unfortunately, prior attempts involving direct oxygen ventilation or aqueous perfusates of fluorocarbons or hemoglobin carriers have failed, leading many researchers to abandon the method. We attribute these prior failures to limited mass transfer of oxygen to the peritoneum and have designed an oxygen formulation that overcomes this limitation. Using phospholipid-coated oxygen microbubbles (OMBs), we demonstrate 100% survival for rats experiencing acute lung trauma to at least 2 h. In contrast, all untreated rats and rats treated with peritoneal oxygenated saline died within 30 min. For rats treated with OMBs, hemoglobin saturation and heart rate were at normal levels over the 2-h timeframe. Peritoneal oxygenation with OMBs was therefore shown to be safe and effective, and the method requires less equipment and technical expertise than initiating and maintaining an extracorporeal circuit. Further translation of peritoneal oxygenation with OMBs may provide therapy for acute respiratory distress syndrome arising from trauma, sepsis, pneumonia, aspiration, burns and other pulmonary diseases.

Indexed as

MicrobubblesPerfusionAnimalsDrug Delivery SystemsLipidsLung InjuryMaleOxygenPeritoneumRatsRats, WistarLipidsOxygenAcute lung injuryAcute respiratory distress syndromeHypoxemiaOxygen absorption and transportPhospholipid monolayer

Identifiers

PMID24439406
PMCPMC7124456
OpenAlexW2037186464

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.