Evidence map›Paper›PMID 24420156›Full record

ArticleInternational orthopaedics2014

Design and kinematics in total knee arthroplasty.

Vitantonio Digennaro, Francesco Zambianchi, Andrea Marcovigi, Raffaele Mugnai, Francesco Fiacchi, Fabio Catani

Abstract readComparative Study
In one paragraph

Article in International orthopaedics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Medial pivot total knee arthroplasty.Journal of clinical orthopaedics and trauma · 2025
    Review
  5. Article
  6. The Effect of the Design of Polyethylene Inserts in Total Knee Arthroplasty on Patient Reported Outcomes.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vitantonio DigennaroDepartment of Orthopaedic Surgery, Azienda Ospedaliero-Universitaria Policlinico di Modena, University of Modena and Reggio-Emilia, Via del Pozzo, 71, 41124, Modena, Italy, digennaro_1977@libero.it.
Francesco Zambianchi
Andrea Marcovigi
Raffaele Mugnai
Francesco Fiacchi
Fabio Catani

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePosterior stabilised (PS) total knee arthroplasty (TKA) design development that focused on restoring normal knee kinematics was followed by the introduction of reason-guided motion designs. Although all PS fixed-bearing knee designs were thought to have similar kinematics, reports show they have differing incidences and magnitudes of posterior femoral rollback and axial rotation. In this retrospective comparative study between two guided-motion total knee systems, we hypothesised that kinematic pattern has an influence on clinical and functional outcomes.

methodsThis study represents the continuation of a previously reported clinical and kinematics analysis. We retrospectively reviewed 347 patients treated with two different TKA designs: Scorpio NRG (Stryker Orthopedics) and Journey Bi-Cruciate Stabilised (BCS) knee system (Smith & Nephew). Two hundred and eighty-one patients were assessed clinically. Patients were divided into groups according to implanted TKA. Clinical evaluation with the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire was performed. Fifteen Scorpio NRG and 16 Journey BCS patients underwent video fluoroscopy during stair climbing, chair rising/sitting and step up/down at six months of follow-up.

resultsAt an average 29 months of clinical follow-up, patients with Journey BCS TKAs reported better clinical results. Stiffness was more frequently reported in the Journey group (5.2 % vs 1.2 %), whereas anterior knee pain was observed in the Scorpio NRG group (1.9 %) only. Both prosthetic models reported different posterior translation of the medial and lateral contact points (CP) in all analysed motor tasks during knee flexion (BCS 10-18 mm; NRG Scorpio 2-3 mm). Both designs produced progressive external rotation of the femoral component relative to the tibia during flexion.

conclusionsJourney BCS showed statistically significant better KOOS results. The higher posterior femoral rollback observed in the kinematic assessment of this design, associated with a better patellofemoral design, may be the reason for better clinical outcome. The reported cases of stiffness and anterolateral joint pain could be attributed to excessive medial and lateral tibiofemoral posterior translation. The NRG group demonstrated good axial rotation, but this was not coupled with physiological kinematic patterns. Patellofemoral pain can be explained by a less friendly femoral-groove design. TKA clinical-functional outcome and complications were highly influenced by the bearing geometry and kinematic pattern of prosthetic designs.

Indexed as

Knee ProsthesisProsthesis DesignArthroplasty, Replacement, KneeBiomechanical PhenomenaCohort StudiesFluoroscopyFollow-Up StudiesHumansKnee JointOsteoarthritis, KneePatient SatisfactionRetrospective StudiesSurveys and QuestionnairesTreatment Outcome

Identifiers

PMID24420156
PMCPMC3923950

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked