ArticleSurgical endoscopy2014
Cost analysis and effectiveness comparing the routine use of intraoperative fluorescent cholangiography with fluoroscopic cholangiogram in patients undergoing laparoscopic cholecystectomy.
Article in Surgical endoscopy, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03860493 (Feasibility of the IC-Flow Device for Fluorescent Perfusion Evaluation During Open Surgical Procedures), which is not on this map. Cited by 51 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Feasibility of the IC-Flow Device for Fluorescent Perfusion Evaluation During Open Surgical Procedures
Who cites it
51 citing papers in PubMed, 7 syntheses or guidelines pooled it, 107 citations in OpenAlex.
- Extrahepatic biliary tract visualization using near-infrared fluorescence imaging with indocyanine green: optimization of dose and dosing time.Surgical endoscopy · 2021Pooled it
- Subtotal cholecystectomy for difficult acute cholecystitis: how to finalize safely by laparoscopy-a systematic review.World journal of emergency surgery : WJES · 2021Pooled it
- Safe cholecystectomy multi-society practice guideline and state-of-the-art consensus conference on prevention of bile duct injury during cholecystectomy.Surgical endoscopy · 2020Guideline
- Optimizing the image of fluorescence cholangiography using ICG: a systematic review and ex vivo experiments.Surgical endoscopy · 2018Pooled it
- Biliary tract visualization using near-infrared imaging with indocyanine green during laparoscopic cholecystectomy: results of a systematic review.Surgical endoscopy · 2017Pooled it
- Utility of fluorescent cholangiography during laparoscopic cholecystectomy: A systematic review.World journal of gastroenterology · 2015Pooled it
- Near-infrared fluorescence imaging for real-time intraoperative anatomical guidance in minimally invasive surgery: a systematic review of the literature.World journal of surgery · 2015Pooled it
- DOse and administration Time of Indocyanine Green in near-infrared fluorescence cholangiography during laparoscopic cholecystectomy (DOTIG): a randomized clinical trial.Surgical endoscopy · 2025Trial
- Routine use of ICG to enhance operative safety in emergency laparoscopic cholecystectomy: a randomized controlled trial.Surgical endoscopy · 2022Trial
- The Best Approach for Laparoscopic Fluorescence Cholangiography: Overview of the Literature and Optimization of Dose and Dosing Time.Surgical innovation · 2017Trial
- How low can you go? Intraoperative microdosing of indocyanine green for fluorescence cholangiography during laparoscopic cholecystectomy.Surgical endoscopy · 2025Article
- High-contrast in vivo fluorescence imaging exploiting wavelengths beyond 1880 nm.Nature communications · 2025Article
- Article
- Knowledge, attitudes and practices of using Indocyanine Green (ICG) fluorescence in emergency surgery: an international web-based survey in the ARtificial Intelligence in Emergency and trauma Surgery (ARIES)-WSES project.Updates in surgery · 2024Article
- Laparoscopic cholecystectomy for a gallbladder with a short cystic duct draining to the accessory right anterior hepatic duct using indocyanine green fluorescence imaging: A case report.International journal of surgery case reports · 2024Article
- Biliary Anatomy Visualization and Surgeon Satisfaction Using Standard Cholangiography versus Indocyanine Green Fluorescent Cholangiography during Elective Laparoscopic Cholecystectomy: A Randomized Controlled Trial.Journal of clinical medicine · 2024Article
- Utility of indocyanine green fluorescent dye in emergency general surgery: a review of the contemporary literature.Frontiers in surgery · 2024Review
- Identification of the ideal weight-based indocyanine green dose for fluorescent cholangiography.Surgical endoscopy · 2023Article
- Indocyanine green fluorescent cholangiography improves the clinical effects of difficult laparoscopic cholecystectomy.Surgical endoscopy · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDespite the standardization of laparoscopic cholecystectomy (LC), the rate of bile duct injury (BDI) has risen from 0.2 to 0.5%. Routine use of intraoperative cholangiography (IOC) has not been widely accepted because of its cost and a lack of evidence concerning its use in preventing BDI. Fluorescent cholangiography (FC), which has recently been advocated as an alternative to IOC, is a novel intraoperative procedure involving infrared visualization of the biliary structures. This study evaluated costs and effectiveness of routinely implemented FC and IOC during LC. MATERIALS AND
methodsBetween February and June 2013, the authors prospectively collected the data of all patients undergoing laparoscopic cholecystectomy. We retrospectively reviewed and compared the use of FC and IOC. Procedure time, procedure cost, and effectiveness of the two methods were analyzed and compared. The surgeons involved in the cases completed a survey on the usefulness of each method.
resultsA total of 43 patients (21 males and 22 females) were analyzed during the study period. Mean age was 49.53 ± 14.35 years and mean body mass index was 28.35 ± 8 kg/m(2). Overall mean operative time was 64.95 ± 17.43 min. FC was faster than IOC (0.71 ± 0.26 vs. 7.15 ± 3.76 min; p < 0.0001). FC was successfully performed in 43 of 43 cases (100%) and IOC in 40 of 43 cases (93.02%). FC was less expensive than IOC (US$14.10 ± 4.31 vs. US$778.43 ± 0.40; p < 0.0001). According to the survey, all surgeons found routine use of FC useful.
conclusionIn this study, FC was effective in delineating important anatomic structures. It required less time and expense than IOC, and was perceived by the surgeons to be easier to perform, and at least as useful as IOC. Further prospective studies are warranted to evaluate the effectiveness of FC in decreasing BDI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.