ArticleLasers in medical science2014
Monitoring of chemotherapy leukemia treatment using Raman spectroscopy and principal component analysis.
Article in Lasers in medical science, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 68 citations in OpenAlex.
- Combined SERS and chemometric analyses of blood plasma and bone marrow towards pediatric leukemia biomarkers detection.Mikrochimica acta · 2026Article
- Single cell Raman spectroscopic profiles predict treatment responses in patients withFrontiers in cell and developmental biology · 2026Article
- SERS and Machine Learning-Enabled Liquid Biopsy: A Promising Tool for Early Detection and Recurrence Prediction in Acute Leukemia.ACS omega · 2025Article
- Pregnancy detection based on blood serum sample Raman spectroscopy.Lasers in medical science · 2024Article
- The Investigation of the Subtle Structural Discrepancies between Oryza Sativa Recombinant and Plasma-Derived Human Serum Albumins to Design a Novel Nanoparticle as a Taxane Delivery System.The protein journal · 2024Article
- Raman spectroscopy combined with multivariate statistical algorithms for the simultaneous screening of cervical and breast cancers.Lasers in medical science · 2024Article
- Label-free atherosclerosis diagnosis through a blood drop of apolipoprotein E knockout mouse model using surface-enhanced Raman spectroscopy validated by machine learning algorithm.Bioengineering & translational medicine · 2023Article
- Rapid and precise detection of cancers via label-free SERS and deep learning.Analytical and bioanalytical chemistry · 2023Article
- Current and Emerging Techniques for Diagnosis and MRD Detection in AML: A Comprehensive Narrative Review.Cancers · 2023Review
- The emerging applications and advancements of Raman spectroscopy in pediatric cancers.Frontiers in oncology · 2023Review
- Discrimination of leukemias and non-leukemic cancers in blood serum samples of children and adolescents using a Raman spectral model.Lasers in medical science · 2022Article
- Elucidating the Heterogeneity of Serum Metabolism in Patients with Myelodysplastic Syndrome and Acute Myeloid Leukemia by Raman Spectroscopy.ACS omega · 2022Article
- Raman Spectroscopy of Carotenoid Compounds for Clinical Applications-A Review.Molecules (Basel, Switzerland) · 2022Review
- Breast cancer chemotherapy treatment monitoring based on serum sample Raman spectroscopy.Lasers in medical science · 2022Article
- Label-Free Sensing with Metal Nanostructure-Based Surface-Enhanced Raman Spectroscopy for Cancer Diagnosis.ACS applied nano materials · 2022Review
- Data-Driven Identification of Biomarkers for In Situ Monitoring of Drug Treatment in Bladder Cancer Organoids.International journal of molecular sciences · 2022Article
- Identification of Lesional Tissues and Nonlesional Tissues in Early Gastric Cancer Endoscopic Submucosal Dissection Specimens Using a Fiber Optic Raman System.Gastroenterology research and practice · 2020Article
- Discrimination of different cancer types clustering Raman spectra by a super paramagnetic stochastic network approach.PloS one · 2019Article
- Type 2 diabetes detection based on serum sample Raman spectroscopy.Lasers in medical science · 2018Article
- Influence of Cobalt Ions on Collagen Gel Formation and Their Interaction with Osteoblasts.ACS omega · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this research, we used the Raman spectroscopy to distinguish between normal and leukemia blood serum and identify the different types of leukemia based on serum biochemistry. In addition, monitoring of patients under chemotherapy leukemia treatment (CHLT) was studied. Blood samples were obtained from seven patients who were clinically diagnosed with three leukemia types and 21 healthy volunteers. In addition, other five leukemia patients were monitored during the CHLT, two patients were declared healthy, one patient suspended it; the health of the other two patients worsened, and no improvement was observed along CHLT. The serum samples were put under an Olympus microscope integrated to the Raman system, and several points were chosen for the Raman measurement. The Horiba Jobin Yvon LabRAM HR800 Raman system is equipped with a liquid nitrogen-cooled detector and a laser of 830 nm with a power irradiation of 17 mW. It is shown that the serum samples from patient with leukemia and from the control group can be discriminated when multivariate statistical methods of principal component analysis (PCA) and linear discriminant analysis (LDA) are applied to their Raman spectra obtaining two large clusters corresponding to the control and leukemia serum samples and three clusters inside the leukemia group associated with the three leukemia types. The major differences between leukemia and control spectra were at 1,338 (Trp, α-helix, phospholipids), 1,447 (lipids), 1,523 (β-carotene), 1,556 (Trp), 1,587 (protein, Tyr), 1,603 (Tyr, Phe), and 1,654 (proteins, amide I, α-helix, phospholipids) cm(-1), where these peaks were less intense in the leukemia spectrum. Minor differences occurred at 661 (glutathione), 890 (glutathione), 973 (glucosamine), 1,126 (protein, phospholipid C-C str), 1,160 (β-carotene), 1,174 (Trp, Phe), 1,208 (Trp), 1,246 (amide III), 1,380 (glucosamine), and 1,404 (glutathione) cm(-1). Leukemia spectrum showed a peak at 917 cm(-1) associated with glutathione, but it was absent in the control spectrum. The results suggest that the Raman spectroscopy and PCA could be a technique with a strong potential of support for current techniques to detect and identify the different leukemia types by using a serum sample. Nevertheless, with the construction of a data library integrated with a large number of leukemia and control Raman spectra obtained from a wide range of healthy and leukemic population, the Raman-PCA technique could be converted into a new technique for minimally invasive real-time diagnosis of leukemia from serum samples. In addition, complementary results suggest that using these techniques is possible to monitor CHLT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.