Evidence map›Paper›PMID 24403996›Full record

ArticleBiomicrofluidics2013

Design criteria for developing low-resource magnetic bead assays using surface tension valves.

Nicholas M Adams, Amy E Creecy, Catherine E Majors, Bathsheba A Wariso, Philip A Short, David W Wright, Frederick R Haselton

Abstract read
In one paragraph

Article in Biomicrofluidics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Phase Diagram Characterization Using Magnetic Beads as Liquid Carriers.Journal of visualized experiments : JoVE · 2015
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nicholas M AdamsDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA ; Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, USA.
Amy E CreecyDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA.
Catherine E MajorsDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA.
Bathsheba A WarisoDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA.
Philip A ShortDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA.
David W WrightDepartment of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, USA.
Frederick R HaseltonDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many assays for biological sample processing and diagnostics are not suitable for use in settings that lack laboratory resources. We have recently described a simple, self-contained format based on magnetic beads for extracting infectious disease biomarkers from complex biological samples, which significantly reduces the time, expertise, and infrastructure required. This self-contained format has the potential to facilitate the application of other laboratory-based sample processing assays in low-resource settings. The technology is enabled by immiscible fluid barriers, or surface tension valves, which stably separate adjacent processing solutions within millimeter-diameter tubing and simultaneously permit the transit of magnetic beads across the interfaces. In this report, we identify the physical parameters of the materials that maximize fluid stability and bead transport and minimize solution carryover. We found that fluid stability is maximized with ≤0.8 mm i.d. tubing, valve fluids of similar density to the adjacent solutions, and tubing with ≤20 dyn/cm surface energy. Maximizing bead transport was achieved using ≥2.4 mm i.d. tubing, mineral oil valve fluid, and a mass of 1-3 mg beads. The amount of solution carryover across a surface tension valve was minimized using ≤0.2 mg of beads, tubing with ≤20 dyn/cm surface energy, and air separators. The most favorable parameter space for valve stability and bead transport was identified by combining our experimental results into a single plot using two dimensionless numbers. A strategy is presented for developing additional self-contained assays based on magnetic beads and surface tension valves for low-resource diagnostic applications.

Identifiers

PMID24403996
PMCPMC3562276

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.