ArticleBiomicrofluidics2013
Empirical chemosensitivity testing in a spheroid model of ovarian cancer using a microfluidics-based multiplex platform.
Article in Biomicrofluidics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Unlocking the Potential of Spheroids in Personalized Medicine: A Systematic Review of Seeding Methodologies.International journal of molecular sciences · 2025Pooled it
- Article
- Insights into high-grade serous carcinoma pathobiology using three-dimensional culture model systems.Journal of ovarian research · 2023Review
- The Applications and Challenges of the Development ofCellular and molecular bioengineering · 2023Review
- In Vitro Models of Ovarian Cancer: Bridging the Gap between Pathophysiology and Mechanistic Models.Biomolecules · 2023Review
- Application of microfluidic chips in anticancer drug screening.Bosnian journal of basic medical sciences · 2022Review
- Droplet microfluidic devices for organized stem cell differentiation into germ cells: capabilities and challenges.Biophysical reviews · 2021Review
- Carboplatin response in preclinical models for ovarian cancer: comparison of 2D monolayers, spheroids, ex vivo tumors and in vivo models.Scientific reports · 2021Article
- Microdissected "cuboids" for microfluidic drug testing of intact tissues.Lab on a chip · 2021Article
- Generation of insulin-secreting organoids: a step toward engineering and transplanting the bioartificial pancreas.Transplant international : official journal of the European Society for Organ Transplantation · 2020Review
- Development of a 3D functional assay and identification of biomarkers, predictive for response of high-grade serous ovarian cancer (HGSOC) patients to poly-ADP ribose polymerase inhibitors (PARPis): targeted therapy.Journal of translational medicine · 2020Article
- Carboplatin sensitivity in epithelial ovarian cancer cell lines: The impact of model systems.PloS one · 2020Article
- Application of microfluidic chip technology in pharmaceutical analysis: A review.Journal of pharmaceutical analysis · 2019Article
- On-chip combined radiotherapy and chemotherapy testing on soft-tissue sarcoma spheroids to study cell death using flow cytometry and clonogenic assay.Scientific reports · 2019Article
- Microphysiologic systems in female reproductive biology.Experimental biology and medicine (Maywood, N.J.) · 2017Review
- In vitro microfluidic models of tumor microenvironment to screen transport of drugs and nanoparticles.Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology · 2017Review
- Simulation-assisted design of microfluidic sample traps for optimal trapping and culture of non-adherent single cells, tissues, and spheroids.Scientific reports · 2017Article
- Electrical Impedance Spectroscopy for Microtissue Spheroid Analysis in Hanging-Drop Networks.ACS sensors · 2016Article
- Drug testing and flow cytometry analysis on a large number of uniform sized tumor spheroids using a microfluidic device.Scientific reports · 2016Article
- Tissue-engineered models of human tumors for cancer research.Expert opinion on drug discovery · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The use of biomarkers to infer drug response in patients is being actively pursued, yet significant challenges with this approach, including the complicated interconnection of pathways, have limited its application. Direct empirical testing of tumor sensitivity would arguably provide a more reliable predictive value, although it has garnered little attention largely due to the technical difficulties associated with this approach. We hypothesize that the application of recently developed microtechnologies, coupled to more complex 3-dimensional cell cultures, could provide a model to address some of these issues. As a proof of concept, we developed a microfluidic device where spheroids of the serous epithelial ovarian cancer cell line TOV112D are entrapped and assayed for their chemoresponse to carboplatin and paclitaxel, two therapeutic agents routinely used for the treatment of ovarian cancer. In order to index the chemoresponse, we analyzed the spatiotemporal evolution of the mortality fraction, as judged by vital dyes and confocal microscopy, within spheroids subjected to different drug concentrations and treatment durations inside the microfluidic device. To reflect microenvironment effects, we tested the effect of exogenous extracellular matrix and serum supplementation during spheroid formation on their chemotherapeutic response. Spheroids displayed augmented chemoresistance in comparison to monolayer culturing. This resistance was further increased by the simultaneous presence of both extracellular matrix and high serum concentration during spheroid formation. Following exposure to chemotherapeutics, cell death profiles were not uniform throughout the spheroid. The highest cell death fraction was found at the center of the spheroid and the lowest at the periphery. Collectively, the results demonstrate the validity of the approach, and provide the basis for further investigation of chemotherapeutic responses in ovarian cancer using microfluidics technology. In the future, such microdevices could provide the framework to assay drug sensitivity in a timeframe suitable for clinical decision making.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.