ArticleRespiratory research2014
Exhaled breath condensate in intubated neonates--a window into the lung's glutathione status.
Article in Respiratory research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 104 citations in OpenAlex.
- Novel biomarkers of fetal and neonatal environmental exposure, effect and susceptibility.Pediatric research · 2025Review
- Collecting exhaled breath condensate from non-ventilated preterm-born infants: a modified method.Pediatric research · 2022Article
- Acetaminophen and the Developing Lung: Could There Be Lifelong Consequences?The Journal of pediatrics · 2021Review
- Enhanced epithelial sodium channel activity in neonatal Scnn1b mouse lung attenuates high oxygen-induced lung injury.American journal of physiology. Lung cellular and molecular physiology · 2021Article
- An omic approach to congenital diaphragmatic hernia: a pilot study of genomic, microRNA, and metabolomic profiling.Journal of perinatology : official journal of the California Perinatal Association · 2020Article
- The Relationship Between Airway Antioxidant Levels, Alcohol Use Disorders, and Cigarette Smoking.Alcoholism, clinical and experimental research · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAnalysis of exhaled breath condensates (EBC) is a non-invasive technique to evaluate biomarkers such as antioxidants in the pediatric population, but limited data exists of its use in intubated patients, particularly newborns. Currently, tracheal aspirate (TA) serves as the gold standard collection modality in critically ill newborns, but this method remains invasive. We tested the hypothesis that glutathione status would positively correlate between EBC and TA collections in intubated newborns in the Newborn Intensive Care Unit (NICU). We also hypothesized that these measurements would be associated with alveolar macrophage (AM) glutathione status in the newborn lung.
methodsReduced glutathione (rGSH), glutathione disulfide (GSSG), and total GSH (rGSH + (2 X GSSG)) were measured in sequential EBC and TA samples from 26 intubated newborns via high performance liquid chromatography (HPLC). Additionally, AM glutathione was evaluated via immunofluorescence. Pearson's correlation coefficient and associated 95% confidence intervals were used to quantify the associations between raw and urea-corrected concentrations in EBC and TA samples and AM staining. Statistical significance was defined as p ≤ 0.05 using two-tailed tests. The sample size was projected to allow for a correlation coefficient of 0.5, with 0.8 power and alpha of 0.05.
resultsEBC was obtainable from intubated newborns without adverse clinical events. EBC samples demonstrated moderate to strong positive correlations with TA samples in terms of rGSH, GSSG and total GSH. Positive correlations between the two sampling sites were observed in both raw and urea-corrected concentrations of rGSH, GSSG and total GSH. AM glutathione staining moderately correlated with GSSG and total GSH status in both the TA and EBC.
conclusionsGSH status in EBC samples of intubated newborns significantly correlated with the GSH status of the TA sample and was reflective of cellular GSH status in this cohort of neonatal patients. Non-invasive EBC sampling of intubated newborns holds promise for monitoring antioxidant status such as GSH in the premature lung. Further studies are necessary to evaluate the potential relationships between EBC biomarkers in the intubated premature newborn and respiratory morbidities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.