Evidence map›Paper›PMID 24392206›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2013

Accuracy Evaluation of a 3D Ultrasound-guided Biopsy System.

Walter J Wooten, Jonathan A Nye, David M Schuster, Peter T Nieh, Viraj A Master, John R Votaw, Baowei Fei

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Ultrasound Frame-to-Volume Registration via Deep Learning for Interventional Guidance.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Walter J WootenDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA.
Jonathan A NyeDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA.
David M SchusterDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA.
Peter T NiehDepartment of Urology, Emory University School of Medicine, Atlanta, GA.
Viraj A MasterDepartment of Urology, Emory University School of Medicine, Atlanta, GA.
John R VotawDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA.
Baowei FeiDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA ; Department of Biomedical Engineering, Emory University and Georgia Institute of Technology ; Department of Mathematics and Computer Science, Emory University, Atlanta, GA.

Funding

uPAR Targeted in Vivo Molecular Magnetic Resonance Imaging of....P50CA128301 · NCI · EMORY UNIVERSITY · PI NYE, JONATHON A · 2008 to 2012
$6.8M
MOLECULAR IMAGING DIRECTED, 3D ULTRASOUND-GUIDED, BIOPSY SYSTEMR01CA156775 · NCI · UNIVERSITY OF TEXAS DALLAS · PI FEI, BAOWEI · 2011 to 2016
$1.7M
NCI NIH HHS P50 CA128301NCI NIH HHS R01 CA156775
6 · The paper itself

Abstract

Early detection of prostate cancer is critical in maximizing the probability of successful treatment. Current systematic biopsy approach takes 12 or more randomly distributed core tissue samples within the prostate and can have a high potential, especially with early disease, for a false negative diagnosis. The purpose of this study is to determine the accuracy of a 3D ultrasound-guided biopsy system. Testing was conducted on prostate phantoms created from an agar mixture which had embedded markers. The phantoms were scanned and the 3D ultrasound system was used to direct the biopsy. Each phantom was analyzed with a CT scan to obtain needle deflection measurements. The deflection experienced throughout the biopsy process was dependent on the depth of the biopsy target. The results for markers at a depth of less than 20 mm, 20-30 mm, and greater than 30 mm were 3.3 mm, 4.7 mm, and 6.2 mm, respectively. This measurement encapsulates the entire biopsy process, from the scanning of the phantom to the firing of the biopsy needle. Increased depth of the biopsy target caused a greater deflection from the intended path in most cases which was due to an angular incidence of the biopsy needle. Although some deflection was present, this system exhibits a clear advantage in the targeted biopsy of prostate cancer and has the potential to reduce the number of false negative biopsies for large lesions.

Indexed as

3D ultrasound imagingphantomProstate biopsyprostate cancertargeted biopsytransrectal ultrasoundultrasound-guided

Identifiers

PMID24392206
PMCPMC3877320

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.