Evidence map›Paper›PMID 24390975›Full record

ArticleJournal of magnetic resonance imaging : JMRI2014

Estimation of the absolute shear stiffness of human lung parenchyma using (1) H spin echo, echo planar MR elastography.

Yogesh K Mariappan, Kevin J Glaser, David L Levin, Robert Vassallo, Rolf D Hubmayr, Carl Mottram, Richard L Ehman, Kiaran P McGee

Abstract readValidation Study
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Article
  2. Review
  3. Imaging the Lung in ARDS: A Primer.Respiratory care · 2024
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. MR elastography: Principles, guidelines, and terminology.Magnetic resonance in medicine · 2021
    Review
  13. Article
  14. Acoustic Methods for Pulmonary Diagnosis.IEEE reviews in biomedical engineering · 2019
    Review
  15. Matrix biomechanics and dynamics in pulmonary fibrosis.Matrix biology : journal of the International Society for Matrix Biology · 2018
    Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yogesh K MariappanPhilips Healthcare, Bangalore, Karnataka, India.
Kevin J Glaser
David L Levin
Robert Vassallo
Rolf D Hubmayr
Carl Mottram
Richard L Ehman
Kiaran P McGee

Funding

Regional Assessment of the Lung Using Magnetic Resonance Elastography (MRE)R01EB007593 · NIBIB · MAYO CLINIC ROCHESTER · PI MCGEE, KIARAN PATRICK · 2009 to 2010
$696k
NIBIB NIH HHS EB007593NIBIB NIH HHS R01 EB007593
6 · The paper itself

Abstract

purposeTo develop a rapid proton MR elastography (MRE) technique that can quantify the absolute shear stiffness of lung parenchyma, to investigate the ability to differentiate respiration-dependent stiffness variations of the lung, and to demonstrate clinical feasibility. MATERIALS AND

methodsA spin-echo echo planar imaging MRE sequence (SE-EPI MRE) with a very short echo time was developed and tested in a series of five healthy volunteers at three different lung volumes: (i) residual volume (RV), (ii) total lung capacity (TLC), (iii) and midway between RV and TLC (MID). At each volume, lung density was quantified using a MR-based density mapping sequence. For reference, data were acquired using the previously described spin-echo lung MRE sequence (SE-MRE). MRE data were also acquired in a patient with proven Idiopathic Pulmonary Fibrosis (IPF) to test clinical feasibility.

resultsThe SE-EPIMRE sequence reduced total acquisition time by a factor of 2 compared with the SE-MRE sequence. Lung parenchyma median shear stiffness for the 5 volunteers quantified with the SE-EPI MRE sequence was 0.9 kPa, 1.1 kPa, and 1.6 kPa at RV, MID, and TLC, respectively. The corresponding values obtained with the SE-MRE sequence were 0.9 kPa, 1.1 kPa, and 1.5 kPa. Absolute shear stiffness was also successfully measured in the IPF patient.

conclusionThe results indicate that stiffness variations due to respiration could be measured with the SE-EPIMRE technique and were equivalent to values generated by the previously described SE-MRE approach. Preliminary data obtained from the patient demonstrate clinical feasibility.

Indexed as

AdultEcho-Planar ImagingElasticity Imaging TechniquesFeasibility StudiesFunctional Residual CapacityHumansImage Processing, Computer-AssistedLungLung Diseases, InterstitialMaleMiddle AgedReference ValuesResidual VolumeShear StrengthTotal Lung Capacityinterstitial lung diseaselung fibrosislung MR elastographymagnetic resonance elastographyshear stiffness

Identifiers

PMID24390975
PMCPMC4019718

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.