Evidence map›Paper›PMID 24381519›Full record

ArticleTheScientificWorldJournal2013

A model of implant-associated infection in the tibial metaphysis of rats.

Maximilian Haenle, Carmen Zietz, Tobias Lindner, Kathleen Arndt, Anika Vetter, Wolfram Mittelmeier, Andreas Podbielski, Rainer Bader

Open access · goldAbstract read
In one paragraph

Article in TheScientificWorldJournal, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Maximilian HaenleDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Carmen ZietzDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Tobias LindnerDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Kathleen ArndtInstitute of Medical Microbiology, Virology and Hygiene, University Rostock, Schillingallee 70, 18057 Rostock, Germany.
Anika VetterDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Wolfram MittelmeierDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Andreas PodbielskiInstitute of Medical Microbiology, Virology and Hygiene, University Rostock, Schillingallee 70, 18057 Rostock, Germany.
Rainer BaderDepartment of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057 Rostock, Germany.
Institute of Medical Microbiology and Hygiene · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveImplant-associated infections remain serious complications in orthopaedic and trauma surgery. A main scientific focus has thus been drawn to the development of anti-infective implant coatings. Animal models of implant-associated infections are considered helpful in the in vivo testing of new anti-infective implant coatings. The aim of the present study was to evaluate a novel animal model for generation of implant-associated infections in the tibial metaphysis of rats. MATERIALS AND

methodsA custom-made conical implant made of Ti6Al4V was inserted bilaterally at the medial proximal tibia of 26 female Sprague-Dawley rats. Staphylococcus aureus in amounts spanning four orders of magnitude and each suspended in 15  μ l phosphate buffered saline (PBS) was inoculated into the inner cavity of the implant after the implantation into the defined position. Controls were treated accordingly with PBS alone. Animals were then followed for six weeks until sacrifice. Implant-associated infection was evaluated by microbiological investigation using swabs and determination of viable bacteria in the bone around the implant and the biofilm on the implants after sonification.

resultsIrrespective of the initial inoculum, all animals in the various groups harbored viable bacteria in the intraoperative swabs as well as the sonication fluid of the implant and the bone samples. No correlation could be established between initially inoculated CFU and population sizes on implant surfaces at sacrifice. However, a significantly higher viable count was observed from peri-implant bone samples for animals inoculated with 10(6) CFU. Macroscopic signs of animal infection (pus and abscess formation) were only observed for implants inoculated with at least 10(5) CFU S. aureus. DISCUSSION/

conclusionThe results demonstrate the feasibility of this novel animal model to induce an implant-associated infection in the metaphysis of rats, even with comparatively low bacterial inocula. The specific design of the implant allows an application of bacteria in reproducible numbers at well-defined contact sites to the animal bone.

Indexed as

TibiaAlloysAnimalsAnti-Bacterial AgentsBiofilmsCoated Materials, BiocompatibleDisease Models, AnimalFemaleProstheses and ImplantsProsthesis-Related InfectionsRatsRats, Sprague-DawleyStaphylococcal InfectionsStaphylococcus aureusTitaniumAlloysAnti-Bacterial AgentsCoated Materials, BiocompatibleTitaniumtitanium alloy (TiAl6V4)

Identifiers

PMID24381519
PMCPMC3871506
OpenAlexW2164950487

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.