ArticlePloS one2013
Force sensing in surgical sutures.
Article in PloS one, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 36 citations in OpenAlex.
- Initial clinical experience with saroa, a haptic feedback-enabled surgical assist robot, in pulmonary anatomical resection.General thoracic and cardiovascular surgery · 2026Observational
- Mechanical Properties of Bioengineered Corneal Stroma.Advanced healthcare materials · 2021Review
- Article
- Quantifying fascial tension in ventral hernia repair and component separation.Hernia : the journal of hernias and abdominal wall surgery · 2021Article
- Suction-fixing surgical device for assisting liver manipulation with laparoscopic forceps.International journal of computer assisted radiology and surgery · 2020Article
- Evaluation of suturing performance in general surgery and ocular microsurgery by combining computer vision-based software and distributed fiber optic strain sensors: a proof-of-concept.International journal of computer assisted radiology and surgery · 2020Article
- Comparison of Artificial Saliva vs Saline Solution on Rate of Suture Degradation in Oropharyngeal Surgery.JAMA otolaryngology-- head & neck surgery · 2018Article
- Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.Sensors (Basel, Switzerland) · 2018Article
- Surgical Dynamometer to Simultaneously Measure the Tension Forces and the Distance between Wound Edges during the Closure of a Laparotomy.Sensors (Basel, Switzerland) · 2018Article
- A New Skin Tensiometer Device: Computational Analyses To Understand Biodynamic Excisional Skin Tension Lines.Scientific reports · 2016Article
- Holding Strength of Suture: An Experimental Study Using Porcine Kidney.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to describe the design and evaluation of the Stitch Force (SF) sensor and the Hook-In Force (HIF) sensor. These sensors were developed to measure the force on a tensioned suture inside a closed incision and to measure the pulling force used to close the incision. The accuracy of both sensors is high enough to determine the relation between the force in the thread of a stitch and the pulling force applied on the suture by the physician. In a pilot study, a continuous suture of 7 stitches was applied on the fascia of the abdominal wall of multiple pigs to study this relationship. The results show that the max force in the thread of the second stitch drops from 3 (SD 1.2) to 1 (SD 0.3) newton after the 4(th) stitch was placed. During placement of the 5(th), 6(th) and 7(th) stitch, the force in the 2(nd) stitch was not influenced anymore. This study indicates that in a continuous suture the force in the thread remains constant up to more than 3 stiches away from the pulled loose end of the suture. When a force feedback tool is developed specially for suturing in surgery on patients, the proposed sensors can be used to determine safety threshold for different types of tissue and sutures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials