Evidence map›Paper›PMID 24370768›Full record

SynthesisClinical journal of the American Society of Nephrology : CJASN2014

Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.

Christopher A Muir, Sradha S Kotwal, Carmel M Hawley, Kevan Polkinghorne, Martin P Gallagher, Paul Snelling, Meg J Jardine

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in Clinical journal of the American Society of Nephrology : CJASN, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
21.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 117 citations in OpenAlex.

  1. Buttonhole versus Stepladder Cannulation for Home Hemodialysis: A Multicenter, Randomized, Pilot Trial.Clinical journal of the American Society of Nephrology : CJASN · 2019
    Trial
  2. A Trial of Extending Hemodialysis Hours and Quality of Life.Journal of the American Society of Nephrology : JASN · 2017
    Trial
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Risk of Vascular Access Infection Associated With Buttonhole Cannulation of Fistulas: Data From the National Healthcare Safety Network.American journal of kidney diseases : the official journal of the National Kidney Foundation · 2020
    Observational
  10. Article
  11. Article
  12. Review
  13. Arteriovenous Vascular Access Selection and Evaluation.Canadian journal of kidney health and disease · 2016
    Article
  14. Article
  15. Article
  16. Should buttonhole cannulation be discontinued?Clinical journal of the American Society of Nephrology : CJASN · 2014
    Article
  17. Article
  18. Kidney medicine
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 7 institutions in 1 country.

Christopher A MuirRenal and Metabolic Division, The George Institute for Global Health, Sydney, Australia;, †Department of Medicine, Blacktown Hospital, Sydney, Australia;, ‡Sydney Medical School, University of Sydney, Sydney, Australia;, §Nephrology Department, Princess Alexandra Hospital, Brisbane, Australia;, ‖Department of Nephrology, Monash Medical Centre, Clayton, Australia;, ¶Departments of Medicine, Epidemiology, and Preventative Medicine, Monash University, Melbourne, Australia;, *Department of Renal Medicine, Concord Repatriation General Hospital, Sydney, Australia, ††Department of Renal Medicine, Royal Prince Alfred Hospital, Sydney, Australia.
Sradha S Kotwal
Carmel M Hawley
Kevan Polkinghorne
Martin P Gallagher
Paul Snelling
Meg J Jardine
Blacktown & Mount Druitt Hospital · AUConcord Repatriation General Hospital · AUMonash Medical Centre · AUPrincess Alexandra Hospital · AURoyal Prince Alfred Hospital · AUThe George Institute for Global Health · AUThe University of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesThe relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, all incident patients were started on buttonhole cannulation, and prevalent patients were converted to this cannulation method. Coprimary outcomes were arteriovenous fistula-attributable systemic infections and a composite of arteriovenous fistula loss or requirement for surgical intervention. Secondary outcomes were total arteriovenous fistula-related infections and staff time requirements. Additionally, a systematic review evaluating infections by cannulation method was performed.

resultsSeventeen systemic arteriovenous fistula-attributable infections were documented in 90 patients who were followed for 3765 arteriovenous fistula-months. Compared with rope ladder, buttonhole was not associated with a significantly higher rate of systemic arteriovenous fistula-attributable infections (incidence rate ratio, 2.71; 95% confidence interval, 0.66 to 11.09; P=0.17). However, use of buttonhole was associated with a significantly higher rate of total arteriovenous fistula infections (incidence rate ratio, 3.85; 95% confidence interval, 1.66 to 12.77; P=0.03). Initial and ongoing staff time requirements were significantly higher with buttonhole cannulation. Arteriovenous fistula loss or requirement for surgical intervention was not different between cannulation methods. A systematic review found increased arteriovenous fistula-related infections with buttonhole compared with rope ladder in four randomized trials (relative risk, 3.34; 95% confidence interval, 0.91 to 12.20), seven observational studies comparing before with after changes (relative risk, 3.15; 95% confidence interval, 1.90 to 5.21), and three observational studies comparing units with different cannulation methods (relative risk, 3.27; 95% confidence interval, 1.44 to 7.43).

conclusionButtonhole cannulation was associated with higher rates of infectious events, increased staff support requirements, and no reduction in surgical arteriovenous fistula interventions compared with rope ladder in home hemodialysis patients. A systematic review of the published literature found that buttonhole is associated with higher risk of arteriovenous fistula-related infections.

Indexed as

Arteriovenous Shunt, SurgicalAdultCatheterizationCatheter-Related InfectionsEquipment DesignFemaleHealth Knowledge, Attitudes, PracticeHemodialysis, HomeHumansKidney Failure, ChronicMaleMiddle AgedNeedlesPatient Education as TopicPuncturesRetrospective Studies

Identifiers

PMID24370768
PMCPMC3878698
OpenAlexW2109975706

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.