Pressures and timing of intermittent pneumatic compression devices for efficient tissue fluid and lymph flow in limbs with lymphedema.

Marzanna Zaleska, Waldemar L Olszewski, Pradeep Jain, Sashi Gogia, Arun Rekha, Samsita Mishra, Marek Durlik

Open access · greenAbstract read
In one paragraph

Article in Lymphatic research and biology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 54 citations in OpenAlex.

  1. [S1 guideline on intermittent pneumatic compression (IPC)].Der Hautarzt; Zeitschrift fur Dermatologie, Venerologie, und verwandte Gebiete · 2018
    Guideline
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Marzanna Zaleska1 Medical Research Centre, Polish Academy of Sciences, Department of Surgery and Epigenetics, Central Clinical Hospital , Warsaw, Poland .
Waldemar L Olszewski
Pradeep Jain
Sashi Gogia
Arun Rekha
Samsita Mishra
Marek Durlik
Central Clinical Hospital · PLNational Institute of Pathology · INAnnamalai University · INBanaras Hindu University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

unlabelledPneumatic compression of tissues with lymph stasis is, aside from the manual massage, a commonly used therapeutic modality in limb lymphedema. A number of pneumatic devices have been constructed. There is lack of reports of comparative studies determining inflation pressure levels, inflation/deflation cycle times, and total pumping times.

aimWe tried to answer the question how high compression pressure and how long compression timing should be applied to the limb soft tissues to reach tissue fluid (TF) head pressure above 30 mmHg, necessary to initiate proximal flow.

methodsTF pressures were measured subcutaneously during intermittent pneumatic compression in the lymphedematous limbs stage II to IV. Pressures of 50, 80, and 120 mmHg and timing 5, 20, and 50 sec were applied.

resultsa) the TF head pressures were lower than those in inflated chambers, b) inflation time of 5 and 20 sec was not long enough to generate TF head pressures above 30 mmHg, even if the compression pressures were as high as 120 mmHg, c) the 50 sec timing allowed to reach head pressures above 30 mmHg; however, they remained always lower than in the compression chamber, d) TF head pressures differed at various levels of the limb depending on the soft tissue mass, e) deflation of the inflated whole sleeve for 5 and 20 sec was followed by high end pressures, whereas that of 50 sec brought about pressure drop to 0, facilitating refilling with TF of the distal parts of the massaged limb.

conclusionsOur observations point to the necessity of applying high pressures and compression times over 50 sec, to generate effective TF pressures and provide enough time for creating TF flow. Short inflation times generate TF pressures as in one-chamber devices that preclude its effectiveness compared to the multi-chamber devices.

Indexed as

Intermittent Pneumatic Compression DevicesManipulation, OsteopathicAdultFemaleHumansLegLymphedemaMaleMassageMiddle AgedPressureRheologyTime FactorsTreatment Outcome

Identifiers

PMID24364846
PMCPMC3875197
OpenAlexW2091857094

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.