ArticleSensors and actuators. B, Chemical2014
Microfluidic Valves Made From Polymerized Polyethylene Glycol Diacrylate.
Article in Sensors and actuators. B, Chemical, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Novel thermoplastic microvalves based on an elastomeric cyclic olefin copolymer.Lab on a chip · 2024Article
- Understanding the Response of Poly(ethylene glycol) diacrylate (PEGDA) Hydrogel Networks: A Statistical Mechanics-Based Framework.Macromolecules · 2024Article
- Review
- Flexible Materials for High-Resolution 3D Printing of Microfluidic Devices with Integrated Droplet Size Regulation.ACS applied materials & interfaces · 2021Article
- Fabrication of Microfluidic Devices for Emulsion Formation by Microstereolithography.Molecules (Basel, Switzerland) · 2021Review
- Three-Dimensional Printed Devices in Droplet Microfluidics.Micromachines · 2019Review
- Surface Modification of Glass/PDMS Microfluidic Valve Assemblies Enhances Valve Electrical Resistance.ACS applied materials & interfaces · 2019Article
- Digital Manufacturing for Microfluidics.Annual review of biomedical engineering · 2019Review
- High-Precision Stereolithography of Biomicrofluidic Devices.Advanced materials technologies · 2019Article
- Design of Controllable Novel Piezoelectric Components for Microfluidic Applications.Sensors (Basel, Switzerland) · 2018Article
- Organs-on-a-Chip Module: A Review from the Development and Applications Perspective.Micromachines · 2018Review
- 3D-printed Quake-style microvalves and micropumps.Lab on a chip · 2018Article
- Normally closed plunger-membrane microvalve self-actuated electrically using a shape memory alloy wire.Microfluidics and nanofluidics · 2018Article
- 3D printed high density, reversible, chip-to-chip microfluidic interconnects.Lab on a chip · 2018Article
- High density 3D printed microfluidic valves, pumps, and multiplexers.Lab on a chip · 2016Article
- 3D-printing of transparent bio-microfluidic devices in PEG-DA.Lab on a chip · 2016Article
- 3D-Printed Microfluidics.Angewandte Chemie (International ed. in English) · 2016Review
- Pressure-actuated microfluidic devices for electrophoretic separation of pre-term birth biomarkers.Analytical and bioanalytical chemistry · 2016Article
- 3D printed microfluidic devices with integrated valves.Biomicrofluidics · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Pneumatically actuated, non-elastomeric membrane valves fabricated from polymerized polyethylene glycol diacrylate (poly-PEGDA) have been characterized for temporal response, valve closure, and long-term durability. A ~100 ms valve opening time and a ~20 ms closure time offer valve operation as fast as 8 Hz with potential for further improvement. Comparison of circular and rectangular valve geometries indicates that the surface area for membrane interaction in the valve region is important for valve performance. After initial fabrication, the fluid pressure required to open a closed circular valve is ~50 kPa higher than the control pressure holding the valve closed. However, after ~1000 actuations to reconfigure polymer chains and increase elasticity in the membrane, the fluid pressure required to open a valve becomes the same as the control pressure holding the valve closed. After these initial conditioning actuations, poly-PEGDA valves show considerable robustness with no change in effective operation after 115,000 actuations. Such valves constructed from non-adsorptive poly-PEGDA could also find use as pumps, for application in small volume assays interfaced with biosensors or impedance detection, for example.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials