Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).

Brendan Loughran, S N Swetadri Vasan, Vivek Singh, Ciprian N Ionita, Amit Jain, Daniel R Bednarek, Albert Titus, Stephen Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Implementation of material decomposition using an EMCCD and CMOS-based micro-CT system.Proceedings of SPIE--the International Society for Optical Engineering · 2017
    Article
  2. Article
  3. Article
  4. Workflow for the use of a high-resolution image detector in endovascular interventional procedures.Proceedings of SPIE--the International Society for Optical Engineering · 2014
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Brendan LoughranToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
S N Swetadri VasanToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Vivek SinghToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Ciprian N IonitaToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Amit JainToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Daniel R BednarekToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Albert TitusToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Stephen RudinToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Toshiba (United States) · US

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
Solid State X-ray Image Intensifier DevelopmentR01EB008425 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2008 to 2011
$2.6M
NIBIB NIH HHS R01 EB002873NIBIB NIH HHS R01 EB008425
6 · The paper itself

Abstract

The detectors that are used for endovascular image-guided interventions (EIGI), particularly for neurovascular interventions, do not provide clinicians with adequate visualization to ensure the best possible treatment outcomes. Developing an improved x-ray imaging detector requires the determination of estimated clinical x-ray entrance exposures to the detector. The range of exposures to the detector in clinical studies was found for the three modes of operation: fluoroscopic mode, high frame-rate digital angiographic mode (HD fluoroscopic mode), and DSA mode. Using these estimated detector exposure ranges and available CMOS detector technical specifications, design requirements were developed to pursue a quantum limited, high resolution, dynamic x-ray detector based on a CMOS sensor with 50 μm pixel size. For the proposed MAF-CMOS, the estimated charge collected within the full exposure range was found to be within the estimated full well capacity of the pixels. Expected instrumentation noise for the proposed detector was estimated to be 50-1,300 electrons. Adding a gain stage such as a light image intensifier would minimize the effect of the estimated instrumentation noise on total image noise but may not be necessary to ensure quantum limited detector operation at low exposure levels. A recursive temporal filter may decrease the effective total noise by 2 to 3 times, allowing for the improved signal to noise ratios at the lowest estimated exposures despite consequent loss in temporal resolution. This work can serve as a guide for further development of dynamic x-ray imaging prototypes or improvements for existing dynamic x-ray imaging systems.

Indexed as

angiographyCMOSdetector designfluoroscopyMAFneurovascular interventionsROIx-ray imaging

Identifiers

PMID24353389
PMCPMC3864963
OpenAlexW1990370545

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.