Evidence map›Paper›PMID 24353387›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2013

Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.

V Singh, S N Swetadri Vasan, A Jain, P Sharma, D R Bednarek, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 89% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

V SinghToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
S N Swetadri VasanToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
A JainToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
P SharmaToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
D R BednarekToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
S RudinToshiba Stoke and Vascular Research Center, University at Buffalo (SUNY), Clinical Translational Research Center, 8 floor, 875 Elicott Street, Buffalo, NY 14203.
Toshiba (United States) · US

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
Solid State X-ray Image Intensifier DevelopmentR01EB008425 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2008 to 2011
$2.6M
NIBIB NIH HHS R01 EB002873NIBIB NIH HHS R01 EB008425
6 · The paper itself

Abstract

The new Solid State X-ray Image Intensifier (SSXII) is a high-resolution, high-sensitivity, real-time region-of-interest (ROI) x-ray imaging detector. Evaluations were made of both standard linear systems metrics (MTF, DQE) and total system performance with generalized linear systems metrics (GMTF, GDQE) including scatter and geometric un-sharpness for simulated clinical conditions. The SSXII is based on a 1k × 1k EMCCD sensor coupled to a 300 µm thick CsI(Tl) phosphor through a 2.88:1 fiber optic taper resulting in a 37 µm effective pixel size and an effective 3.7 cm × 3.7 cm square field-of-view (FOV). Standard methods were used to calculate MTF, NNPS and DQE. Generalized metrics were calculated and compared for three different magnifications (1.03, 1.11 and 1.2) and three different focal spots (0.3 mm, 0.5 mm and 0.8 mm) for a scatter fraction of 0.28. For an RQA5 spectrum, at 5 cycles/mm the MTF was found to be 0.06 and DQE was 0.04, while the DQE(0) was 0.60. Focal spot un-sharpness and scatter significantly degrades the GMTF and GDQE performance of the detector. A low frequency drop is caused by scatter and is almost independent of focal spot size and magnification. The degradation for middle range frequencies is caused by geometric un-sharpness and increases with focal spot size and magnification. This degradation was least in the case of the small focal spot and almost independent of magnification. In spite of this degradation, the high resolution SSXII with a small FOV may have a significant impact on ROI image-guided neuro-interventions since it demonstrates far better performance than standard current detectors.

Indexed as

DQEgeneralized metricsgeometric un-sharpnessimage qualityMTFrelative detectabilitysystem optimization

Identifiers

PMID24353387
PMCPMC3864936
OpenAlexW2018729324

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked