ArticleJournal of diabetes science and technology2013
Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.
Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01871831 (Prüfung Von Blutzuckermesssystemen - Bewertung Der Sauerstoffabhängigkeit), which is not on this map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prüfung Von Blutzuckermesssystemen - Bewertung Der Sauerstoffabhängigkeit
Who cites it
11 citing papers in PubMed, 27 citations in OpenAlex.
- The Impact of Interfering Substances on Continuous Glucose Monitors Part 3: A Review of Non-Labeled Substances Influencing Continuous Glucose Monitor Readings.Journal of diabetes science and technology · 2026Review
- Clinical Accuracy of a Glucose Oxidase-Based Blood Glucose Test-Strip Across Extremes of Oxygen Partial Pressure.Journal of diabetes science and technology · 2024Article
- Distribution of Oxygen Partial Pressures in Native Capillary Fingertip Blood Samples From a Large Diabetes Patient Population.Journal of diabetes science and technology · 2023Article
- In Vitro Evaluation of Miniaturized Amperometric Enzyme Sensor Based on the Direct Electron Transfer Principle for Continuous Glucose Monitoring.Journal of diabetes science and technology · 2022Article
- Monitoring of Pediatric Type 1 Diabetes.Frontiers in endocrinology · 2020Review
- Proof of Concept Study to Assess the Influence of Oxygen Partial Pressure in Capillary Blood on SMBG Measurements.Journal of diabetes science and technology · 2019Article
- Evaluation of Hematocrit Influence on Self-Monitoring of Blood Glucose Based on ISO 15197:2013: Comparison of a Novel System With Five Systems With Different Hematocrit Ranges.Journal of diabetes science and technology · 2018Article
- Pilots and Diabetes Technology.Journal of diabetes science and technology · 2017Article
- Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge.Journal of diabetes science and technology · 2016Review
- Structural analysis of fungus-derived FAD glucose dehydrogenase.Scientific reports · 2015Article
- Glucose homeostasis during short-term and prolonged exposure to high altitudes.Endocrine reviews · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPartial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not.
methodsAliquots of 20 venous samples were adjusted to the following pO2 values: <45, ~70, and ≥150 mmHg. For each system, five consecutive measurements on each sample aliquot were performed using the same test strip lot. Relative differences between the mean BG results at pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 <45 and ≥150 mmHg were calculated.
resultsFor all tested GOx systems, mean relative differences in the BG measurement results were between 6.1% and 22.6% at pO2 <45 mmHg and between -7.9% and -14.9% at pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p < .0001). The GDH system showed mean relative differences of -1.0% and -0.4% at pO2 values <45 and ≥150 mmHg, respectively, which were not significant.
conclusionsThese data suggest that capillary blood pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.