ArticleJournal of diabetes science and technology2013
Artificial pancreas: model predictive control design from clinical experience.
Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Pooled it
- Accuracy of a CGM Sensor in Pediatric Subjects With Type 1 Diabetes. Comparison of Three Insertion Sites: Arm, Abdomen, and Gluteus.Journal of diabetes science and technology · 2017Trial
- The importance of interpreting machine learning models for blood glucose prediction in diabetes: an analysis using SHAP.Scientific reports · 2023Article
- Uncovering personalized glucose responses and circadian rhythms from multiple wearable biosensors with Bayesian dynamical modeling.Cell reports methods · 2023Article
- Synthetic biomedical data generation in support ofFrontiers in big data · 2023Review
- Review
- Blood glucose concentration control for type 1 diabetic patients: a multiple-model strategy.IET systems biology · 2020Article
- Development platform for artificial pancreas algorithms.PloS one · 2020Article
- Adaptive and Personalized Plasma Insulin Concentration Estimation for Artificial Pancreas Systems.Journal of diabetes science and technology · 2018Article
- Event-Triggered Model Predictive Control for Embedded Artificial Pancreas Systems.IEEE transactions on bio-medical engineering · 2018Article
- Fractional calculus in pharmacokinetics.Journal of pharmacokinetics and pharmacodynamics · 2018Article
- Prediabetes in youth - mechanisms and biomarkers.The Lancet. Child & adolescent health · 2017Article
- Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.Diabetes technology & therapeutics · 2016Review
- Designing an artificial pancreas architecture: the AP@home experience.Medical & biological engineering & computing · 2015Article
- Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.Medical & biological engineering & computing · 2015Article
- Multicenter closed-loop/hybrid meal bolus insulin delivery with type 1 diabetes.Diabetes technology & therapeutics · 2014Article
- Monitoring Artificial Pancreas Trials Through Agent-based Technologies: A Case Report.Journal of diabetes science and technology · 2014Article
- Predictive Control of the Blood Glucose Level in Type I Diabetic Patient Using Delay Differential Equation Wang Model.Journal of medical signals and sensorsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe objective of this research is to develop a new artificial pancreas that takes into account the experience accumulated during more than 5000 h of closed-loop control in several clinical research centers. The main objective is to reduce the mean glucose value without exacerbating hypo phenomena. Controller design and in silico testing were performed on a new virtual population of the University of Virginia/Padova simulator.
methodsA new sensor model was developed based on the Comparison of Two Artificial Pancreas Systems for Closed-Loop Blood Glucose Control versus Open-Loop Control in Patients with Type 1 Diabetes trial AP@home data. The Kalman filter incorporated in the controller has been tuned using plasma and pump insulin as well as plasma and continuous glucose monitoring measures collected in clinical research centers. New constraints describing clinical knowledge not incorporated in the simulator but very critical in real patients (e.g., pump shutoff) have been introduced. The proposed model predictive control (MPC) is characterized by a low computational burden and memory requirements, and it is ready for an embedded implementation.
resultsThe new MPC was tested with an intensive simulation study on the University of Virginia/Padova simulator equipped with a new virtual population. It was also used in some preliminary outpatient pilot trials. The obtained results are very promising in terms of mean glucose and number of patients in the critical zone of the control variability grid analysis.
conclusionsThe proposed MPC improves on the performance of a previous controller already tested in several experiments in the AP@home and JDRF projects. This algorithm complemented with a safety supervision module is a significant step toward deploying artificial pancreases into outpatient environments for extended periods of time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.